Technical realization
4.4.5
S300 Mini safety laser scanner
Status information
Meaning/effect
Warning field bit [WF]
•
Logical 1, if both warning fields of the S300
Mini are unoccupied
•
Logical 0, if one of the warning fields of the
S300 Mini is infringed
Protective field [PF]
•
Logical 1, if the protective field is unoccupied
Warning field 1 [WF1]
•
Logical 1, if the active allocated warning field is
unoccupied
Warning field 2 [WF2]
•
Logical 1, if the active allocated warning field is
unoccupied
Contamination [Weak]
•
Logical 1, if the optics cover is contaminated
I/O error [I/O Error]
•
Logical 0, if there is no error on the S300 Mini
•
Logical 1, if there is an error on the S300 Mini
Tab. 21: Status information