Chapter
4
Technical information
EFI
20
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8012622/Z098/2016-11-07
Subject to change without notice
Technical realization
Description of bit 0 to 7 of byte 0
Byte 0
0.0
0.1
3)
0.2
3)
0.3
0.4
0.5
0.6
0.7
General
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD1
OSSD2
Warning
Field 1
Weak
(pollution
warning)
Reset Switch
Input (button
pressed)
C4000 receiver
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD1 (HW
OSSD State)
OSSD2
(virtual)
Not used
Weak
(pollution
warning)
Reset Switch
Input
M4000 receiver
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD1 (HW
OSSD State)
OSSD2
(virtual)
Not used
Weak
(pollution
warning)
Reset Switch
Input
≥V01.20
Reset/RES/
OVR Switch
Input (MI2)
S3000 in
compatibility
mode
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD
S3000_1
OSSD
S3000_2
Status
Warning
Field
Weak
(pollution
warning)
Reset (button
pressed)
S3000
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD
Speed
Valid Status
Warning
Field 1
Weak
(pollution
warning)
Reset (button
pressed)
S3000 Anti
Collision
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD
Speed Valid Not used
Weak
(pollution
warning)
Reset (button
pressed)
S300 in
compatibility
mode
4)
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD
S300_1
OSSD
S300_2
Status
Warning
Field 1
Weak
(pollution
warning)
Reset (button
pressed)
S300
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
OSSD
Speed
Valid Status
Warning
Field
Weak
(pollution
warning)
Reset (button
pressed)
S300 Mini
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
Not used
Not used
Status
Warning
Field
Weak
(pollution
warning)
Not used
UE402
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
0
0
Input Pin B1
conditional
Override
(identical to
bit info tech
in terminal
status)
Input Pin B2
conditional
Override
(identical to
bit info tech
in terminal
status)
0
UE403
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
0
0
Not used
(Input Pin B1
Bypass)
Not used
(Input Pin B2
Bypass)
RES/OVR
Switch Input
(UI2)
UE4740
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
Byte 0, Bit 3
Byte 0, Bit 4 Byte 0, Bit 5
Byte 0, Bit 6 Byte 0, Bit 7
Flexi Soft
Dynamic
Counter
Dynamic
Counter
Dynamic
Counter
Byte 0, Bit 3
Byte 0, Bit 4 Byte 0, Bit 5
Byte 0, Bit 6 Byte 0, Bit 7
Tab. 7: Byte 0 of the EFI communication
3)
Bit is device internal predefined. Read only.