Approach
b
Add the DIP switches of rows A, B and C that are set to On.
°
If the sum of the DIP switches is even, keep the setting of DIP switch 4 (row
C).
°
If the sum of the DIP switches is odd, change the setting of DIP switch 4 (row
C).
Example
On one device, cross-muting and the beam coding (code 1) was configured. DIP switch
4 (row C) is in the OFF state.
b
Sum of the DIP switches (rows A ... C), that are set to ON = 1.
DIP switches 1 and 2 (row D) for the beam coding are not included.
✓
The sum of the DIP switches is odd.
b
Set DIP switch 4 (row C) to ON.
7.7
Configuring the restart interlock
Prerequisites
•
A reset pushbutton is connected
•
The device is not in the override or override required status
Approach
NOTE
Skip the first and second steps if the device is already in configuration mode.
1.
Disconnect the device from the voltage supply.
2.
Switch on the voltage supply, then continue with the next step within 30 s.
If more than 30 s elapses, start with step 1 again.
3.
Press the reset pushbutton for between 1 and 3 s, then release it.
If the reset pushbutton is pressed for more than 3 s, start with step 1 again.
✓
The device is in configuration mode, the INFO LED flashes green.
✓
Diagnostic LED 4 flashes white and signals that the restart interlock has been con‐
figured.
✓
The restart interlock is configured. The reset pushbutton must remain at the con‐
nection to which it was connected during configuration.
4.
Disconnect the device from the voltage supply.
✓
The device can now be put into operation.
To deactivate restart interlock, reset the active unit to the factory settings.
Complementary information
The restart interlock is deactivated on delivery.
If muting is configured, the same button is used for reset and override. The button must
be connected to the 8-pin system connection.
When the restart interlock is configured, the application diagnostic output located on
the same plug connector as the reset pushbutton signals when the reset pushbutton
needs to be pressed. The application diagnostic output signals “Reset required” and
periodically switches between HIGH and LOW so that any suitable lamp that is con‐
nected flashes.
CONFIGURATION
7
8024782/2019-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
71