Table 26: SP1 system plug extension connection pin assignment (M12 female connector, 5-pin)
PIN
Wire color
1)
s
Sender
r
Receiver
1
Brown
24 V Out (voltage supply
output)
2)
24 V Out (voltage supply
output)
2)
2
White
Not assigned
In1
(Single system or last
guest: EDM [EDM input]
Host or first of 2 guests:
OSSD input)
3
Blue
0 V Out (voltage supply out‐
put)
0 V Out (voltage supply out‐
put)
4
Black
Sync-Out (cascade synchro‐
nization output)
In2
(Single system or last
guest: RES [reset pushbut‐
ton input]
Host or first of 2 guests:
OSSD input)
5
Gray
MFP2 (cascade communi‐
cation)
MFP2
(Single system or last
guest: ADO [application
diagnostic output] / IO-Link
Host or first of 2 guests:
cascade communication)
1)
Applies to the connecting cables recommended as accessories.
2)
Only for cascading deTec devices, not suitable for connecting other devices.
Table 27: SP2 system plug extension connection pin assignment (M12 female connector, 5-pin)
PIN
Wire color
1)
r
Receiver
1
Brown
24 V Out (voltage supply
output)
2)
2
White
In1
(Single system: EDM [EDM
input]
3)
/ muting signal 1
Host: OSSD input)
3
Blue
0 V Out (voltage supply out‐
put)
4
Black
In2
(Single system: RES [reset
pushbutton input] / muting
signal 2
Host: OSSD input)
5
Gray
MFP2
(Single system: ADO [appli‐
cation diagnostic output] /
IO-Link
Host: cascade communica‐
tion)
1)
Applies to the connecting cables recommended as accessories.
2)
Only for cascading deTec devices, not suitable for connecting other devices.
3)
When muting is configured, EDM is not possible at the extension connection.
Further topics
•
"Integration in electrical control", page 54
6
ELECTRICAL INSTALLATION
90
O P E R A T I N G I N S T R U C T I O N S | deTec4
8021645/1EB0/2022-04-28 | SICK
Subject to change without notice