LEDs
End cap with
integrated
LED
Meaning
OSSD
Field
Diagnostic LEDs
1
2
3
4
5
6
7
8
O
White
(3 s)
Scanning range
adjustment is con‐
figured.
O
Red
Ö
Ö
Yellow/
green
o
o
o
o
o
o
o
o
Ö
Ö
Yel‐
low/green
Reset of the con‐
figuration to fac‐
tory settings is acti‐
vated,
.
O
Red
Ö
Green
Ö
Green
Device is in con‐
figuration mode,
see "Configuration
mode", page 95
When a function
is configured, the
corresponding diag‐
nostic LED flashes.
o
LED off.
Ö
LED flashes.
O
LED illuminates. Empty cells mean that the LED lights up, flashes, or is off.
After the configuration is displayed, diagnostic LEDs 1, 2, 3 and 4 indicate the align‐
ment quality. Additionally, the synchronization status of the topmost and bottommost
beams of the safety light curtain are displayed by means of diagnostic LEDs 5 and 6 as
well as 7 and 8.
If the configuration was changed, the diagnostic LEDs flash white for 3 s upon activa‐
tion.
Once the safety light curtain is aligned and the protective field is clear (field indicator:
flashing yellow or lit up green), the alignment quality display switches off after a certain
period of time.
Table 44: Indication of the alignment quality
LEDs
Meaning
Diagnostics LEDs
1
2
3
4
5
6
7
8
o
o
o
o
o
o
o
o
Alignment is inadequate, or the protective field is
at least partially interrupted. The receiver cannot
synchronize with the sender.
O
Blue
o
o
o
At least one beam is synchronized.
However, the alignment is inadequate, or the pro‐
tective field is at least partially interrupted.
O
Blue
O
Blue
o
o
The alignment or the signal strength is still not
sufficient for stable availability, or the protective
field is at least partially interrupted.
1)
O
Blue
O
Blue
O
Blue
o
Alignment is good, stable availability.
1)
2)
O
Blue
O
Blue
O
Blue
O
Blue
Alignment is very good.
1)
O
Blue
O
Blue
The topmost light beam (far from system plug) is
synchronized.
11
TROUBLESHOOTING
126
O P E R A T I N G I N S T R U C T I O N S | deTec4
8021645/1EB0/2022-04-28 | SICK
Subject to change without notice