Complementary information
External device monitoring is deactivated on delivery.
Further topics
•
"External device monitoring (EDM)", page 57
•
7.14
Configuring application diagnostic output
Overview
The application diagnostic outputs are configured automatically:
The following signals can be output over the application diagnostic output:
•
Reset required
•
Weak signal
•
Ignored object
•
Muting status
•
Override required
•
Valid object for Smart Box Detection
A signal can be output on both the system and extension connections.
Table 39: Output signals on the system connection and extension connection
Configured function
Output signal on the application
diagnostic output of the system
connection
Output signal on the application
diagnostic output of the extension
connection
Not configured (fac‐
tory settings)
Weak signal
1)
Weak signal
1)
Reduced resolution
Ignored object
2)
Weak signal
1)
Restart interlock with
reset pushbutton on
the system connection
Reset required
Weak signal
1)
Restart interlock with
reset pushbutton on
the extension connec‐
tion
Weak signal
1)
or ignored object
2)
Reset required
Muting on In1 and In2 Override required
Muting condition or override
required
Muting on In2 and In4 Muting status or override required Muting status or override required
Muting on In1 and In2
and restart interlock
with reset pushbutton
on the system connec‐
tion
Reset required or override
required
Muting status or reset required or
override required
Muting on In2 and In4
and restart interlock
with reset pushbutton
on the system connec‐
tion
Muting status or reset required or
override required
Muting status or reset required or
override required
Smart Box Detection
Override required
Valid object required for Smart
Box Detection or Override
Smart Box Detection
and restart interlock
with reset pushbutton
on the system connec‐
tion
Reset required or override
required
Valid object for Smart Box Detec‐
tion or Reset required or Override
required
CONFIGURATION
7
8021645/1EB0/2022-04-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTec4
105