LEDs
End cap with inte‐
grated LED
Meaning
OSSD Field
Diagnostics LEDs
1
2
3
4
5
6
7
8
O
Red
Ö
Ö
Yel‐
low/r
ed
Ö
Ö
Yellow/red
Smart Box Detection
Override required.
An object has been
detected in the pro‐
tective field while the
OSSDs are in the
OFF state.
o
LED off.
Ö
LED flashes.
O
LED illuminates. Empty cells mean that the LED lights up, flashes, or is off.
If front screen contamination increases in ongoing operation, the laser alignment aid
switches on or the alignment takes longer than 3 seconds, the receiver shows the
alignment quality again.
Further topics
•
"Indication of the alignment quality", page 114
11.3.3
Fault indicators
Overview
In the event of a fault, the type of fault is indicated by the LED display on the sender or
receiver.
The information in the tables applies both for single devices and for every device in a
cascade.
When a device in a cascade shows a fault, the displays of the other devices in the
cascade must also be observed. The fault cause is only shown on the device in which it
occurs.
Sender
Position of the LEDs:
see "Sender displays", page 21
Table 46: Fault indication on the sender
LEDs
Possible cause
Troubleshooting
STATE
Field
O
Yellow
o
Normal operation, no cable connec‐
tion between sender and receiver.
1)
–
O
Yellow
Ö
Red
Fault in the voltage supply.
b
Check the voltage supply,
b
Switch the voltage supply off and
back on again.
b
If the fault persists, replace the
sender,
Ö
Yellow
Ö
Red
The sender identified an internal
fault.
b
Switch the voltage supply off and
back on again.
b
If the fault persists, replace the
sender,
O
Red
Ö
Ö
Yellow/green
Reset of the configuration to factory
settings is activated.
For additional information:
.
11
TROUBLESHOOTING
132
O P E R A T I N G I N S T R U C T I O N S | deTec4
8021645/1EB0/2022-04-28 | SICK
Subject to change without notice