O P E R AT I N G I N S T R U C T I O N S |
Bulkscan LMS511
8014829/ZJ56/2017-02-15|
S I C K
Subject to change without notice
8 8
APPENDIX
outHeight
Bulk height
Parameter
Variable type Value range
Unit
Lower limit
float_32
0 … 20
m
Upper limit
float_32
0 … 20
m
Lower hysteresis
float_32
5 … 95
%
Upper hysteresis
float_32
5 … 95
%
outDensity
Bulk density
Parameter
Variable type Value range
Unit
Lower limit
float_32
0 to 50
t/m³
Upper limit
float_32
0 to 50
t/m³
Lower hysteresis
float_32
5 to 95
%
Upper hysteresis
float_32
5 to 95
%
outSpeed
Belt speed
Parameter
Variable type Value range
Unit
Lower limit
float_32
0 to 30
m/s
Upper limit
float_32
0 to 30
m/s
Lower hysteresis
float_32
5 to 95
%
Upper hysteresis
float_32
5 to 95
%
13.1.12
Reference measurement (compensation function)
Permissible commands:
sRN, sEN
Variable name
Description
Variable type Value range
Unit
ccStatus
Status of the reference mea-
surement
uint_8
0: Deactivated
1: Active
ccMeasVolume1
Measured volume
(reference measurement 1
to 10)
float_32
m³
ccMeasVolume2
ccMeasVolume3
ccMeasVolume4
ccMeasVolume5
ccMeasVolume6
ccMeasVolume7
ccMeasVolume8
ccMeasVolume9
ccMeasVolume10