O P E R AT I N G I N S T R U C T I O N S |
Bulkscan LMS511
8014829/ZNC5/2017-06-06 |
S I C K
Subject to change without notice
2 4
CONFIGURABLE FUNCTIONS
How to configure the calculation of the distance from the conveyor belt edges:
On the
Operating mode
configuration bar, click
Maintenance
to switch to mainte-
nance mode.
Switch to the
Edge monitoring
tab. Set the limits of the monitored area (
left field
ends
at and
right field ends
at) so that the entire monitoring area can still be co-
vered.
Or:
Switch to the Monitor tab. Click and drag the outside left or right edge beam to the
required aperture angle
Configure the upper and lower monitoring limits for the left and right belt edges (
Up-
per limit
and
Lower limit
) in the Edge detection tab.
Configure the
Averaging filter
Distance to edge
, if required.
How to configure the signaling of belt edge warnings :
Switch to the
Edge monitoring
tab.
Configure the
Distance from the left edge
and the
Distance from the right edge
from
which a warning is issued.
Switch to the
Interfaces
tab.
Click on
Digital outputs
to open the
Digital outputs
tab (see "4.13 Digital outputs“
Select the assignment
Information/Warnings
for the required output.
Select the required
Logic
.
Select the required
Warning
(
All, Conveyor edge left
or
Conveyor edge right
).
Configure the
Switching delay
, if required.
4.11
Averaging filter
The Bulkscan smooths the measured values for the calculation of the
Flow, Center of
gravity
,
Bulk height
,
Belt speed
and
Distance to edge
using an averaging filter over the
previous n seconds.
The
Flow
averaging filter affects both the results for the
Volume flow rate
and the
Mass
flow rate
. You can configure the period for the averaging.
•
Set the required averaging filter to 0 seconds to disable the filter.
•
Measurement tab
, A
veraging filter group
,
Flow
,
Center of gravity, Bulk height, Belt
speed
or
Distance to edge
option.
4.12
Digital inputs
The Bulkscan has two digital inputs which are used to signal the belt operation and
reset the volume sum and mass sum.
How to configure the signaling of the belt operation:
Switch to the
Measurement
tab.
Configure the
Belt speed
as
Fixed value
(see "4.1 Setting the belt speed“ on page
Check the
Use status signal
checkbox.
Configure the
Logic
for the digital input signal.
Alternatively, you can also make the configuration settings in the
Digital inputs
tab
How to configure the resetting of volume sum and mass sum:
Switch to the
Interfaces
tab.
Click on
Digital inputs
to open the
Digital inputs
tab.
Configure the
Switching condition
of the digital input signal.
Note
Note