ELECTRICAL INSTALLATION
Other connection cables may have different wire colors.
Encoder input 1 is connected to encoder output A (0°).
Encoder input 2 is connected to encoder output B (90°).
6.2.3
Ethernet interface connection
1
2
4
3
Fig. 19: Pin assignment of the "Ethernet" connection (M12×4 socket, D coded)
Pin
Signal
Function
1
TX+
T
2
Rx+
R
3
TX-
Transmit -
4
Rx-
Receive -
Tab. 7: Pin assignment of the "Ethernet" connection
Pre-assembled connection cables are available as accessories (see "12.2 Accessories“
on page 77).
Other connection cables may have different wire colors.
6.2.4
Serial interface connection
Fig. 20: Pin assignment of the "Data" connection (M12×12 plug, A coded)
Pin
Wire color
Signal
Function
1
Brown
24 V EXT
Power supply digital outputs 1 + 2
2
Blue
RD–/RxD
RS-422/485/RS-232
3
White
OUT1
Digital output
1 )
4
Green
GND RS
GND serial data
5
Pink
OUT2
Digital output 2
1)
6
Yellow
Reserved
Do not use
7
Black
TD–/TxD
RS-422/485/RS-232
8
Gray
Reserved
Do not use
9
Red
RD+
RS-422/485
10
Violet
TD+
RS-422/485
11
Gray/pink
Reserved
Do not use
12
Red/blue
Reserved
Do not use
Tab. 8: Pin assignment of the "Data" connection