APPENDIX
13.1.11
Digital outputs
Permissible commands:
sRN, sWN
Variable name
Description
Variable
type
Value range
Unit
out1Assignment
out2Assignment
out3Assignment
out4Assignment
out5Assignment
out6Assignment
Assignment of the
digital outputs (1
to 6)
uint_8
0: Off
1: Information/
warnings
2: Volume quota
3: Mass quota
4: Volume flow rate
5: Mass flow rate
6: Center of gravity
7: Bulk height
8: Bulk density
9: Belt speed
DO1Logic
DO2Logic
DO3Logic
DO4Logic
DO5Logic
DO6Logic
Logic of the digital
outputs (1 to 6)
uint_8
0: Active high
1: Active low
outVolumeQuota
Volume quota per
pulse
float_32
0.01 to 10
6
m³/Inc
outMassQuota
Mass quota per pulse
float_32
0.01 to 10
6
t/Inc
Variable name
Description
Variable type Value range
Unit
outVolumeFlow
Volume flow rate
Parameter
Variable type Value range
Unit
Lower limit
float_32
–10
6
to
10
6
m³/h
Upper limit
float_32
–10
6
to
10
6
m³/h
Lower hysteresis
float_32
5 to 95
%
Upper hysteresis
float_32
5 to 95
%
outMassFlow
Mass flow rate
Parameter
Variable type Value range
Unit
Lower limit
float_32
–10
6
to
10
6
t/h
Upper limit
float_32
–10
6
to
10
6
t/h
Lower hysteresis
float_32
5 to 95
%
Upper hysteresis
float_32
5 to 95
%