Operating instructions
M21/HB M27/GB
Page 20
SHT Heiztechnik aus Salzburg GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40 Tel. 0662-450444-0, Fax-DW 9
Our current general terms and conditions apply.Errors, printing faults and technical changes reserved
•
Adjust Dom.Water temperatures
Loading Stop 55°C:
This value is adjustable! The Domestic hot water is heated at every loading
process to that value.
Loading Start 45°C:
This value is adjustable! If the Domestic hot water temperature falls below
this value during "High temperature" (see "Dom.Water Monitor"), the
loading process starts.
Loading Start 35°C:
This value is adjustable! If the Domestic hot water temperature falls below
this value during "Low temperature" (see "Dom.Water Monitor"), the
loading process starts.
Le:
If requested, here the so-called legionella function can be activated. If
"YES" is selected, the word "Day" is displayed.
Day:
Via this field, the day can be selected on which the legionella killing should
take place (see section "Menu map"). Additionally, the legionella killing
temperature can be set.
Timeprog:
Via this field you access the frame "Dom.Water Timeprog".
•
Domestic hot water legionella function
Day:
This value is adjustable! Setting of the day on which the temperature is
heated further up in order to kill possibly existing legionella bacteria.
Heating up to 65°C:
This value is adjustable!
NOTICE: Below 65°C the killing of the bacteria cannot be ensured!