Comparison output selection
The number of HI-LO limits can be changed.
Correspondence between comparison screens and external I/O output terminals.
How to set
A2
A3
A4
A5
A6
H4 / L0
HI-4
HI-3
OK
HI-2
HI-1
H3 / L1
HI-3
HI-2
OK
HI-1
LO
H2 / L2
HH
HI
OK
LO
LL
H1 / L3
HI
LO-1
OK
LO-2
LO-3
H0 / L4
LO-1
LO-2
OK
LO-3
LO-4
Mode
HI limit operation LO limit operation
H4 / L0
HI-1 to HI-4
None
H3 / L1
HI-1 to HI-3
LO
H2 / L2
HH, HI
LO, LL
H1 / L3
HI
LO-1 to LO-3
H0 / L4
None
LO-1 to LO-4
The HI limit output is turned on when the indicated value becomes larger than the set value.
The LO limit output is turned on when the indicated value becomes smaller than the set value.
SET.
Comp. Setting
Page 2
→
→
Work Setting
→
[HI-0, LO-4]
[HI-1, LO-3]
[HI-2, LO-2]
[HI-3, LO-1]
[HI-4, LO-0]
[Setting]
[Comparison]
Summary of Contents for DS-6200