18.
A: Average hold
B: Valley hold
The average of and the minimum value in the section specified by the SECTION signal are
held.
The value is maintained until the T/H signal turns ON.
19.
A: Average hold
B: P-P hold
The average of and the difference between the maximum value and minimum value in the
section specified by the SECTION signal are held.
The value is maintained until the T/H signal turns ON.
Sensor Input Value
Hold Value A
Hold Value B
Status Display
Status Display
OFF
VLLY
(
B
)
OFF
Blink
ON
OFF
HOLD
(
B
)
OFF
ON
OFF
AVE
(
A
)
OFF
Blink
ON
HOLD
(
A
)
OFF
ON
Status Display
Status Display
OFF
H/E
T/H
SECTION
Sensor Input Value
Hold Value A
Hold Value B
Status Display
Status Display
Status Display
OFF
P-P
(
B
)
OFF
Blink
ON
OFF
HOLD
(
B
)
OFF
ON
OFF
AVE
(
A
)
OFF
Blink
ON
HOLD
(
A
)
OFF
ON
OFF
Status Display
SECTION
T/H
H/E