The higher the resolution, the better the detail and the greater the amount of data.
High Resolution
Medium Resolution
Low Resolution
5.2.4.
Turntable
Check "With Turntable" on the left side of the scan settings and click it to turn on/off the turntable.
Turntable Steps
Turntable step
Before scanning, set the turntable steps from 8 to 180.
The number shows how many times the
turntable will stop in one turn, and the data will get captured at each stop. The default setting, 8 steps,
is recommended. You can change the number of steps according to the features of the objects.
Note
: Using more turntable steps will help scan more complete data in some angles, but NOT more
accurate.
Turntable Speed
Turntable speed
Set to adjust turntable speed. "6" is set by default. Higher value is with higher speed.
Skip Turntable Location Verify:
Use existing axis calibration data. After it is enabled, the existing axis data will be used for alignment
directly. If it is not enabled, it needs to be re-calibrated before scanning and aligning. If the scanning
object or turntable has not been moved, this function can be turned on. If the scanning object or
turntable has been moved, please turn off this function and re-calibrate.
5.2.5.
Alignment Mode
Select an alignment mode condition for the turntable scan.