21
<Note>
When installing the air cleaner cap, install with the arrow of the "TOP" label facing
upwards.
Clean within a shorter period if using in an area with a large amount of dust.
Air cleaner element part no.: 1G659-11221
(Kubota part no.)
Air Cleaner Element Cleaning Notes
< If dried dust is adhering >
Blow compressed air from the inside of the element.
< If carbon or oil is adhering >
Replace with a new part.
9-4. Fuel Filter (Clean/Replace)
Close the fuel lever.
Turn the retainer ring to the left, and remove the
cup and element.
Remove any water or foreign material from inside
the cup and blow compressed air on the element to
clean it. (Or replace the element.)
Re-assemble to the original state.
<Note>
When installing the cup, check that no foreign material is adhering to the packing.
After installing, open the fuel lever and be sure to check that there is no fuel leakage
before closing the lever.
Element part no.: 16271-43561 (Kubota part no.)
9-5. Fuel Tank (Drain Water)
Remove the fuel drain plug.
Drain the water and then tighten the fuel drain plug.
<Note>
Replace the packing with new packing every time you drain the water.
Packing part no.: 6C090-58961 (Kubota part no.)
After tightening the fuel drain plug, be sure to always check that there is no fuel leakage.
Clean
1st time
:
50th hour
/
2nd time and after
:
Every 100 hours
Replace
Every 400 hours
Drain water
Every 200 hours
1
2
3
4
1
2
Fuel Drain Plug
Packing
Air Cleaner Cap
Air Cleaner Element
1
Fuel Lever
Cup
Retainer Ring
Open
Close
Summary of Contents for IDG3100M
Page 2: ......
Page 28: ...25 2017 ...