13
6-5. Battery Inspection
Check the level of the fluid and add distilled water
when it is near the lower level until it reaches the
upper level.
Check the terminals for looseness and tighten if
loose.
<Note>
The battery must be charged when the specific gravity of the battery fluid is 1.23 or less.
Please contact the authorized distributor where this generator was purchased or one of
our sales offices.
Battery Replacement Procedures
Remove the [-] side cable. (Be sure to always
remove the [-] side first.)
Remove the [+] side cable.
Remove the battery hold-down clamp.
Remove the battery.
* Install the battery by performing these procedures
in the reverse order. (Install the [+] side cable first.)
<Note>
Use a "GS Yuasa 44B19L".
1
2
1
2
3
4
Upper
Level
Lower
Level
Terminals
Insulation Cap
Hold-Down
Clamp
Battery
[-] Post
[+] Post
Wear rubber gloves and other protective wear to protect eyes, skin and
clothing from the battery fluid which contains diluted sulfuric acid.
If battery fluid contacts eyes or skin, wash out immediately with an ample
amount of clean water, and be sure to receive medical treatment.
WARNING: EYE/SKIN INJURY
Never use or recharge the battery if the fluid is below the lower level.
Do not create sparks or allow flame near the battery because it
generates flammable gas.
WARNING: EXPLOSION