126
Appendix 1 Parameter list
Parameter list
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User setting
value
Reference
page
Torque boost
0~30%
0.1%
(Note 1)
P40
Maximum frequency
0~120Hz
0.01Hz
120Hz
P41
Minimum frequency
0~120Hz
0.01Hz
0Hz
P41
Base frequency
0~400Hz
0.01Hz
50Hz/60Hz
(Note 2)
P41
Speed 1 (high speed)
0~400Hz
0.01Hz
60Hz
P43
Speed 2 (
medium
speed)
0~400Hz
0.01Hz
30Hz
P43
Speed 3 (low speed)
0~400Hz
0.01Hz
10Hz
P43
Acceleration time
0~360.00s/
0~3600.0s
0.01s/0.1s
5s
P44
Deceleration time
0~360.00s/
0~3600.0s
0.1s/0.01s
5s
P44
Electronic thermal relay
capacity
0~500A
0.01A
Motors rated current
(Note 1)
P46
DC
injection
brake
operation frequency
0~120Hz
0.01Hz
3Hz
P46
DC
injection
brake
operation time
0~60
s
0.1
s
0.5
s
P46
DC
injection
brake
operation voltage
0~30%
0.1%
4%
P46
0~60Hz
0.01Hz
0.5Hz
P47
0~13
1
0
P48
0~400Hz
0.01Hz
5Hz
P51
JOG
acceleration
/
deceleration time
0~360.00s/
0~3600.0s
0.1s/0.01s
0.5s
P51
Input signal across terminal
4-5 selection
0
、
1
1
0
P51
High-speed
maximum
frequency
120~400Hz
0.01Hz
120Hz
P41
0~1000V, 9999
0.1V
9999
P41
Acceleration/deceleration
reference frequency
1~400Hz
0.01Hz
50Hz/60Hz
(Note 2)
P44
Acceleration/deceleration
time increments
0,1
1
0
P44
Stall prevention operation
level
0~400%
0.1%
200%
P52
compensation
factor
at
level reduction
0~200%, 9999
0.1%
9999
P52
0~400Hz, 9999
0.01Hz
9999
P43