Introduction of Inverter
2.5 Installation and wiring
2.5.1 Transport
Take the pedestal when carrying and don’t only take the cover or any part of the inverter,
otherwise it may drop down.
2.5.2 Stockpile
This product before installing must be placed in the packaging, if not use, in order to meet the
company's warranty scope and future maintenance, you must pay attention to the following matters
when storage:
1.
Must be placed in dry and without dirt place.
2. The environment temperature for storage position must range from -20
℃
to +65
℃
.
3. The relative humidity for storage position must range from 0% to 95%, and no condensation.
4. Avoid storing in the environment which contains corrosion gas or liquid.
5. It had better be packed properly and kept on shelf or table.
Note: 1. Even if the humidity meets the standard requirements, icing and condensation can also occur when the
temperature changes rapidly. And the place should avoid.
2. Don't place it on the ground, and it should be placed on appropriate shelf. If in the bad surroundings, the
desiccant should be placed in the packaging bag.
3. If the custody period is more than 3 months, the ambient temperature should not be higher than 30
℃
. It is
to consider that the character will easily degrade in high temperature when the electrolytic capacitors are
deposited without electricity.
4. If the inverter is installed in device or control board when not in use (especially in construction site or the
humid and dusty place), the inverter should be removed and put in suitable environment according with
the above storage conditions.
5. If the electrolytic capacitors are long-term no electricity, the character will degrade. Do not place it in the
state of no electricity for more than one year.
2.5.3 EMC Installation instructions
Inverter is the same as other electrical and electronic equipment, when working in a distribution
system, it is both the electromagnetic interference
sources and the electromagnetic receiver. The
working principle of inverter determines that it will produce certain electromagnetic interference
noise.
In order to guarantee the inverter working reliably in the electromagnetic environment, it must
have a certain abilitily of anti-electromagnetic interference in design. In order to make the drive
system work normaly, and meet
CE declared requirements, please meet the following several aspects
requirements in installation:
1. Field wiring
Power line supply electric independently from power transformer, five core or four core line are
generally used, null line and ground sharing a single line is forbidden.