48
4. Parameter description
Parameter
Time
Output
frequency
(
Hz
)
P.13
Startup signal input
4.9
Load Pattern Selection (P.14, P.98, P.99, P.162~P.169)
P.14 “Load pattern selection”
P.98 “Middle frequency 1”
P.99 “Output voltage 1 of middle
frequency”
P.162 “Middle frequency 2”
P.163 “Output voltage 2 of middle
frequency”
P.164 “Middle frequency 3”
P.165 “Output voltage 3 of middle
frequency”
P.166 “Middle frequency 4”
P.167 “Output voltage 4 of middle
frequency”
P.168 “Middle frequency 5”
P.169 “Output voltage 5 of middle
frequency”
Related parameters
P. 46
“
The second torque boost
”
P. 80~P. 84 , P. 86
“
Multi-function terminals selection
”
P. 0
“
Torque boost
”
Parameter
Factory setting
Setting range
Remarks
14
0
0~13
When P.14=5~13, it provides 9 kinds
of different VF curve.
98
3Hz
0~400Hz (Note 3)
---
99
10%
0~100%
---
162
9999
0~400Hz, 9999 (Note 3)
---
163
0%
0~100%
---
164
9999
0~400Hz, 9999 (Note 3)
---
165
0%
0~100%
---
166
9999
0~400Hz, 9999 (Note 3)
---
167
0%
0~100%
---
168
9999
0~400Hz, 9999 (Note 3)
---
169
0%
0~100%
---