EXTERNAL CLEANING AND VISUAL INSPECTION OF THE FIXTURE

All users of the SGM fixtures should regularly clean those parts of the fixture directly exposed to 
the elements, such as the external housing and front lenses. Additionally, all owners of the SGM 
fixtures must periodically check the external housing of the fixture for structural breaks, deteri

-

oration, cracked lenses, or loose screws. To ensure proper operation, but also to prevent the risk 
of potential accidents, do not use the fixture if the lens, housing, or power cables are damaged. 
If parts of the fixture appear to be missing, cease use immediately and contact SGM support.

WIRING AND CONDUIT/ CONTAINMENT

SGM fixtures supplied with power and data cable leads are not intended for installation in per

-

manently installed conduit or containment. When installing the fixtures in a permanent instal

-

lation, ensure cable leads are installed as a service loop to an appropriately rated junction box 
using suitable cable strain reliefs/glands. All installed fixtures must be securely mounted, and 
service loop appropriately protected for installation location. All electrical wiring and connec

-

tions should be completed by a qualified electrician.

SAFETY PRECAUTIONS

When using electrical equipment, basic safety precautions should always be followed including 
the following:

• 

Do not mount near gas or electric heaters.

• 

Permanently installed equipment should be mounted in locations and at heights where 

it will not be readily subjected to tampering by unauthorized personnel.

• 

The use of accessory equipment not recommended by the manufacturer may cause an 

unsafe condition.

• 

Do not use this equipment for other than intended use.

• 

Refer service to qualified personnel or authorized service centers.

• 

Do not look directly into the beam for long periods of time, when the fixture is on.

• 

The fixture shall, under no circumstance, be covered with insulating material of any kind.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

Summary of Contents for i-6

Page 1: ...USERMANUAL i 6 Product Version 1 0 Document Revision A Released 2022 4 21...

Page 2: ...s available at www sgmlight com or upon request via support sgmlight com The information in this document is subject to change without notice SGM and all affiliated companies disclaim liability for an...

Page 3: ...POI All dimensions in millimetres and inches Drawing not to scale 320mm 12 60in 111mm 4 37in 150mm 5 91in 166mm 6 53in 220mm 8 66in 209 172mm 6 78in 326mm 12 82in 401mm 15 77in 468mm 18 41in 81mm 3 19...

Page 4: ...ter 12 Signal priority 13 INSTALLATION POI FIXTURE 13 Identification and terminology 14 Unpacking 14 Application considerations 14 Connecting temporary Power 14 Connecting temporary signal 15 Settings...

Page 5: ...ION 28 FIXTURE PROPERTIES 28 Factory default 28 LED Engine 28 Individual fixture settings 30 CONTROL MENU 32 RDM 32 Supported RDM functions 32 Sensors 33 ACCESSORIES 33 Anti glare shields 33 MAINTENAN...

Page 6: ...from objects to be illuminated Install only in accordance with applicable building codes Ensure a minimum clearance of 0 3 m 12 in around the cooling fans Do not paint cover or modify the device and d...

Page 7: ...ower and data cable leads are not intended for installation in per manently installed conduit or containment When installing the fixtures in a permanent instal lation ensure cable leads are installed...

Page 8: ...ice IDENTIFICATION AND TERMINOLOGY B A A 24 LEDs 5 Red 5 Green 5 Blue 9 White B Tilt lock C Cooling fans D Control panel POI n a E OLED Display POI n a F Rubber feet POI n a G GORE TEX membrane H Powe...

Page 9: ...e ventilation It is not immersed or submerged in water TRANSPORT HANDLING Always use the supplied packaging or suitable flight case for transportation and storage Never carry the fixture by connected...

Page 10: ...d a lock nut For longer term installations choose outdoor rated hardware 3 Align the omega bracket with the i 6 Series base For standard Omega Bracket insert the fasteners into the i 6 Series base bra...

Page 11: ...t wing screws one on each side by turning them counter clockwise Tilt the fixture to the angle desired and hold it Lock the position by re tightening both tilt lock screws clock wise CAUTION ALWAYS LE...

Page 12: ...ed male and female 5 pin XLR plugs For outdoor installa tions use only IP rated XLR connectors suitable for outdoor use Terminate the DMX out cable of the last fixture in the data link with a 120 ohm...

Page 13: ...cts This is subject to change without notice B A A 24 LEDs 5 Red 5 Green 5 Blue 9 White B Tilt lock C Cooling fans D Rubber feet POI n a E GORE TEX membrane F Power in and out G DMX in and out H LED I...

Page 14: ...mporary programming a plug or terminals can be used The power cable color coding is shown to the left Connect the black wire to live Connect the white wire to neutral Connect the green yellow wire to...

Page 15: ...and look for the green light to illuminate on the fixture If the green light does not appear cycle power or refer to troubleshooting STEP 2 Select the standard settings tab and enter a DMX address an...

Page 16: ...Green Orange Red Fixture is resetting and error s has occurred during reset Blinking Green Red Reset has completed but error s occurred during reset Solid Red 3 seconds Hall sensor is activated When a...

Page 17: ...talled in any orientation and it might take up to two brackets per fixture Depending on the structure please use appropriate and secure methods for mounting the Omega brackets 159mm 6 26in 106mm 4 17i...

Page 18: ...ET ATTACHMENT M10 Countersunk Bolts Flat Bracket 8mm or smaller screw or bolt to structure 8mm or smaller screw or bolt to structure 13mm 0 5in hole diameter for attachment point M10 Stainless Steel B...

Page 19: ...ys use 2 bolts with washers Using a bolt through this slot the fixture will rotate around its center point always use 2 bolts with washers PLEASE NOTE THE UNIVERSAL BRACKET HAS DIFFERENT SLOT CURVES F...

Page 20: ...n to the surface Using the holes shown use appropriately rated fasteners for both location and surface material and construction Fasten ers should be no larger than M6 Use the supplied countersunk M10...

Page 21: ...nose keys The fixture can be tilted in any orientation To adjust the tilt angle in POI fixtures Loosen the two tilt lock kobs one on each side by turning them counter clockwise using the small pig no...

Page 22: ...ut the SGM POI DMX cable For permanent installations have a qualified electrician wire the mains cable directly to a suitable branch circuit For a temporary installation the mains cable may be fitted...

Page 23: ...indicator and wait for 3 sec onds The LED indicator will blink orange for 1 2 seconds before switching to static green again The fixture can now be paired to a new transmitter STEP 2 Select connect or...

Page 24: ...n Control menu Before turning on the i 6 make sure the power cable is properly connected When the fixture is powered on it will boot and reset before displaying the selected operating mode and DMX sta...

Page 25: ...erational mode B DMX address C External data indicator DMX D External data protocol next available DMX address Figure 17 i 6 Display EXTERNAL DATA PROTOCOL D Shows the external data protocol CRMX or D...

Page 26: ...first 6 DMX channels including channel 101 the next avail able channel is 107 101 6 107 107 If two or more i 6s have the same DMX start address they will behave identically Incorrect settings will re...

Page 27: ...e pro grams can be defined and run from the menus and one of the pro grams can be set to run by default whenever the fixture is powered on Each of the three available standalone programs contains 24 u...

Page 28: ...dimming curve Flipping the OLED display If the fixture is installed hanging upside down it is useful to flip the display so that it is easier to read To flip the display press ENTER and select SETTING...

Page 29: ...e refresh rate frequency of the LEDs to be Dimmer optimized low frequency flicker can occur on cameras highest dimming resolution High frequency optimized low dimming resolution flicker is unlikely to...

Page 30: ...ss log off Send Log off command to the CRMX System BRIDGE DMX Displays strength of the wireless connection Startup Mode Select Startup Mode Default operating mode when fixture is powered on STARTUP MO...

Page 31: ...selected scene 1 24 Red Red value in currently selected scene 0 255 Green Green value in currently selected scene 0 255 Blue Blue value in currently selected scene 0 255 Strobe Strobe blinders intens...

Page 32: ...t control over the supported parameters See the tables below for supported RDM functions PLEASE NOTE THE RDM CONTROLLER COMMUNICATES WITH THE FIXTURES TO SHOW ONLY THE AVAILABLE OPTIONS FOR EACH RDM F...

Page 33: ...for all SGM IP rated fixtures made for testing the IP integrity upon reassembly In order to ensure the IP rating of the i 6 Series it s highly recom mended that the fixture is always vacuum tested aft...

Page 34: ...on the SGM website Connect either Std or POI uploader cable depending on which is more suitable for the installation Launch SGM Firmware Tool on a windows PC Click File then Open and navigate to the f...

Page 35: ...aning as they can cause damage to hard ware cables and connectors The level of cleaning required will vary greatly depending on the operating environment and installation Therefore it is recommended t...

Page 36: ...tions DMX cables was disconnected Inspect DMX cables Fixture operates irregularly abnor mal DMX cable polarization is inverted pin 2 3 Reverse the polarity DMX link is not terminated Install a XLR 120...

Page 37: ...76 i 6 RGBW 2 3deg POI CU P N 80251777 i 6 RGBW 3 4deg POI CU P N 80251792 i 6 RGBW 3 4deg POI WH P N 80251791 i 6 RGBW 3 4deg POI BL P N 80251790 i 6 White POI I 6 W 2 3deg POI CU P N 80251782 I 6 W...

Page 38: ...2011 65 EU RoHS2 Directive Pending ANSI UL Std 1573 Pending CSA Std C22 2 No 166 The information in this document is subject to chance without notice For the latest information visit www sgmlight com...

Page 39: ...39 Product Version 1 0 Revision A Released 2022 4 21 USER NOTES...

Page 40: ...40 Product Version 1 0 Revision A Released 2022 4 21 SGM LIGHT A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Reviews: