11
Product Version 1.0 | Revision A | Released 2022-4-21
fully attached to the base.
4.
Hang the fixture on a truss or other structure. Tighten the clamp/bracket.
5.
Verify that there are no combustible materials, cables, or surfaces to be illuminated within 0.3 m (12 in.) of the
fixture.
6.
Check that there is no risk of the head/yoke colliding with other fixtures or structures.
Fasten a safety wire (not shown) between the load-bearing support
structure and the safety wire attachment point on the device.
•
The safety cable (not included in the package) must:
•
Bear at least 10 times the weight of the device (SWL).
•
Have a minimum gauge of 4 mm.
•
Have a maximum length (free fall) = 30 cm (12 in.).
Figure 4: Safety wire attachment point
The fixture head can pivot through 209°.
To adjust the tilt angle in standard versions:
•
Loosen the two tilt wing-screws (one on each side) by turning
them counter-clockwise.
•
Tilt the fixture to the angle desired and hold it.
•
Lock the position by re-tightening both tilt lock screws clock
-
wise.
CAUTION!
ALWAYS LEAVE A FIXTURE TO COOL OFF FOR 15 MIN
-
UTES AFTER OPERATION BEFORE HANDLING.
Figure 5:
i-6
Standard tilt lock
Pitch angle
indicator
TILT LOCK
POWER REQUIREMENTS
The i-6
can operate on any 100–277 V, 50/60 Hz AC mains power supply, and draws a maximum of 250W.
Connect the fixture to AC power by installing a power connector to the bare end side of the supplied power cable.
Connect the powercon twist-lock connector side to the fixture. The fixture must be grounded/earthed and be able to
be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
WARNING! ALWAYS SECURE AN ELEVATED FIXTURE WITH A SAFETY WIRE.
ALWAYS USE A SAFETY WIRE OF A GRADE AISI 316 STEEL.MAKE SURE THE
SLACK OF THE SAFETY WIRE IS AT A MINIMUM.NEVER USE THE YOKE/HANDLE
FOR SECONDARY ATTACHMENT.