Page 33 of 60
SGM-101F - programming menu
10-PROGRAMMING MENU
10.0 M00 - Instantaneous fl ow rate and total net displaying
Displaying only. The display shows the instantaneous
fl
ow rate and net
totalizer value. The “*R” symbol indicates that the transducers echo signal
quality is good; The “*H” symbol indicates that the transducers echo signal
quality is insuf
fi
cient to ensure the correct
fl
ow measurement.
Flow. 25.36 m3/h *R
NET. 24780x1 m3
10.1 M01 - Instantaneous fl ow rate and velocity displaying
Displaying only. The display shows the instantaneous
fl
ow rate and the
fl
uid velocity value in the pipe.
Flow. 25.36 m3/h *R
Vel. 1.6841x1 m/s
10.2 M02 - Instantaneous fl ow rate and forward tot. displaying
Displaying only. The display shows the instantaneous
fl
ow rate and
forward totalizer (POS) value.
Flow. 25.36 m3/h *R
POS. 32562x1 m3
10.3 M03 - Instantaneous fl ow rate and reverse tot. displaying
Displaying only. The display shows the instantaneous
fl
ow rate and
reverse totalizer (NEG) value.
Flow 25.36 m3/h *R
NEG. 7782x1 m3
10.4 M04 - Instantaneous fl ow rate with date and time
displaying
Displaying only. The display shows the instantaneous
fl
ow rate value and
the date (year-month-day) and time (hours: minutes: seconds).
14-04-26 15:43:15 *R
Flow 25.36 m3/h
10.5 M05 - Heat meter totalizer displaying
(for specifi c version only)
Displaying only. The display shows the energy
fl
ow and Heat meter
totalizer value.
EFR 2.2450 GJ/h *R
E.T.
12E+0 GJ
10.6 M06 - T1 and T2 displaying (Heat meter only)
Displaying only. The display shows the T1 and T2 inputs.
T1= 32.812C, 112.76
T2= 32.812C, 112.76
10.7 M07 - AL3 and AL4 analog input displaying
NOT AVAILABLE.
AI3= 0.0152, 0.0729
AI4= 0.0152, 0.0729
10.8 M08 - Measurement status and error codes displaying
Displaying only. The display shows the system codes and messages.
A summary codes table is on page 55.
*H--------------------H--
Poor Signal Detected
10.9 M09 - Daily totalizer displaying
Displaying only. The display shows the daily
fl
ow totalizer.
Net Flow Today M09
592 m3
10.10 M10 - Pipe outer circumference programming
The display shows the previously set value. By entering a new value, the
system will automatically calculate the pipe outer diameter new value
(M11).
Pipe Outer Perimeter
314.159
mm