Page 10 of 60
SGM-101F -
dimensions / pipe specifi cations
5-PIPE SPECIFICATIONS
5.1 OUTSIDE PIPE DIAMETER
In the event that an appropriate instrument to measure the pipe outer diameter is not available
(programming in M11), proceed as follows:
- use a rope or paper tape or sheet
- wrap the pipe with rope or paper tape or sheet and mark the circumference point
- measure the length corresponding to the pipe circumference
- enter the measured value to “Pipe Outer Perimeter” menu (M10), SGM-101F will automatically calculate
the correct pipe diameter value
5.2 PIPE THICKNESS
Value measured on site using an appropriate tool (caliper, ecc.), or from the technical data of the hydraulic
circuit (programming in M12). In the presence of tubes without inner lining, is possible to use the SGM-100T thi-
ckness gauge.
5.3 PIPE MATERIAL
Value detectable on site, or from the technical data of the hydraulic circuit (programming in M14).
5.4 INNER LINING MATERIAL
Value detectable on site, or from the technical data of the hydraulic circuit (programming in M15).
5.5 INNER LINING THICKNESS
Value measured on site using an appropriate tool (caliper, ecc.), or from the technical data of the hydraulic
circuit (programming in M16).
Transducer Type
Features
PT100
Dimensions
185
Ø5
100
¼" G
Temperature
-40 ÷ +160°C
PT100
Dimensions
185
Ø5
50
¼" G
Temperature