Page 29 of 60
SGM-101F -
confi guration
M00
Instantaneous
fl
ow rate and total net displaying
M53
AL5 analog input displaying
M01
Instantaneous
fl
ow rate and velocity displaying
M54
OCT output pulse width programming
M02
Instantaneous
fl
ow rate and forward tot. displaying
M55
Analog output mode programming
M03
Instantaneous
fl
ow rate and reverse tot. displaying
M56
4mA (or 0mA) output programming
M04
Instantaneous
fl
ow rate with date and time displaying
M57
20mA output programming
M05
Heat meter totalizer displaying (for speci
fi
c version only)
M58
Analog output simulation
M06
T1 and T2 displaying (Heat meter only)
M59
Analog output status displaying
M07
AL3 and AL4 analog input displaying
M60
System date and time programming
M08
Measurement status and error codes displaying
M61
SGM101-F info displaying
M09
Daily totalizer displaying
M62
Serial port con
fi
guration programming
M10
Pipe outer circumference programming
M63
Communication protocol programming
M11
Pipe outer diameter programming
M64
AL3 analog input programming
M12
Pipe thickness programming
M65
AL4 analog input programming
M13
Pipe inner diameter programming
M66
AL5 analog input programming
M14
Pipe material programming
M67
Frequency output range programming
M15
Pipe material sound velocity programming (*)
M68
Frequency output low
fl
ow rate programming
M16
Pipe inner lining material programming
M69
Frequency output high
fl
ow rate programming
M17
Inner lining material sound velocity programming (**)
M70
Backlight interval programming
M18
Pipe inner lining thickness programming
M71
LCD contrast programming
M19
Inner ABS thickness programming
M72
Operation time displaying
M20
Fluid type programming
M73
#1 Q min. alarm programming
M21
Fluid sound velocity programming (***)
M74
#1 Q max. alarm programming
M22
Fluid viscosity programming (***)
M75
#2 Q min. alarm programming
M23
Transducers type programming
M76
#2 Q max. alarm programming
M24
Transducers mounting method programming
M77
Buzzer operation programming
M25
Transducers mounting distance displaying
M78
OCT output programming
M26
Data storage mode programming
M79
Relay output programming
M27
Default settings library
M80
Batch output programming
M28
HOLD mode programming
M81
Batch volume programming
M29
Empty pipe condition threshold programming
M82
SGM-101F unit events displaying
M30
Measurement units standard programming
M83
Totalizers automatic correction Enabling
M31
Instantaneous
fl
ow rate unit programming
M84
Heat meter unit programming
M32
Totalizers unit programming
M85
Temperature sensor input programming
M33
Totalizers multiplier programming
M86
Speci
fi
c heat programming
M34
Net totalizer activation programming
M87
Heat meter totalizer programming
M35
Forward totalizer activation programming
M88
Heat meter totalizer multiplier programming
M36
Reverse totalizer activation programming
M89
Temperature differential displaying
M37
Totalizers reset
M90
Transducers signal power and quality displaying
M38
Partial totalizer
M91
TOM/TOS % displaying
M39
Language menu programming
M92
Sound velocity in the
fl
uid displaying
M40
Damping programming
M93
Flight time and delta T.
M41
Low
fl
ow cut-off programming
M94
Reynolds number displaying
M42
Zero
fl
ow automatic calibration
M+0
Date/time/
fl
ow displaying when the unit was power off
M43
Zero
fl
ow calibration reset
M+1
Total operating time displaying
M44
Zero
fl
ow manual calibration
M+2
Last power off date/time displaying
M45
Correction factor programming
M+3
Last measured
fl
ow rate displaying
M46
MODBUS network address programming
M+4
SGM-101F on/off times number displaying
M47
Protection password programming
M+5
Calculator and converter
M48
Calibration data programming
M+6
Velocity threshold programming
M49
MODBUS serial port test
M+7
Monthly totalizer displaying
M50
Data logger programming
M+8
Annual totalizer displaying
M51
Data logger timer programming
M+9
Echo absence error total time displaying (*H)
M52
Data transmission programming
(*) Available only with 9 option selected in
M15
(**) Available only with 11 option selected in
M16
(***) Available only with 8 option selected in
M20
9.4 PROGRAMMING MENU TABLE