6-8. Command Mode
Under “Command Mode”, Indicator will recognize the receipt of Order based on 02h(Header) and
03h(END) signal, and transfers ACK(06)/ NAK(15).
6-8-1. Read Command (Standard Serial Port and Optional Port is same.)
※
Caution : Please use Capital Letter to input Command.
※
Each “READ” Command’s interval must be guaranteed at least 100ms. If you command
another one within 100ms, the indicator will not response. (Under “Check-Sum”, the
interval will be 150ms).
P.C ->> SI 4410
Command
SI 4410 Response
STX ID NO. RCWT ETX
Current Weight
Current Weight Transfer
-STX ID NO. RCWT ST/US,NT/GS
Current
Weight(7/8byte) weight unit(2byte)
ETX
STX ID NO. RCWD ETX
Indicator Memory
Indicator Memory data Transfer
-STX ID NO. RCWD
DATE(6byte) TIME(6byte)
P/N(2byte) S/N(6byte) TARE(7/8byte) current
weight(7/8byte) weight unit(2byte)
ETX
STX ID NO. RFTT ETX
All Set values
All Set values Transfer
-STX ID NO. RFTT
FINAL(7/8byte), PRE1(7/8byte),
PRE2(7/8byte), FREE FALL(5byte)
ETX
STX ID NO. RSUB ETX
SUB-Total Data
SUB-Total Data Transfer
-STX ID NO. RSUB
P/N(2byte) Accumulated
Count(6byte) Accumulated Weight(11byte) Weight
Unit(2byte)
ETX
STX ID NO. RGRD ETX
GRAND Total Data
GRAND Total Data Transfer
-STX ID NO. RGRD
P/N(2byte) Accumulated
Count(6byte) Accumulated Weight(11byte) Weight
Unit(2byte)
ETX
STX ID NO. RSNO ETX
S/N Data
(Accumulated data)
S/N Data Transfer(For Current P/N)
-STX ID NO. RSNO
Accumulated Count(6byte)
ETX