- 33 -
Zero Tracking Compensation Range setting
F04 2
0
∫
9
Due to external causes(Temperature, wind, and dust), there are small weight
difference, indicator will ignore the weight difference and display Zero.
For this compensation function, indicator will estimate the weight
difference is over the set range during fixed time period.
If there is large weight difference over set range within fixed time period,
the “Zero” is breaking and will find new zero point.
Example) Max. Capacity : 100.00kg, Digit : 0.05kg, F04-03 setting
Zero Tracking Compensation Range : 0.5
ⅹ
digit
ⅹ
F04 set value = 0.0025
ⅹ
3 =
0.075kg
Fixed time period : about 5msec. (Fixed time period will be effected on F06(digital filter) setting)
Auto Zero Range setting
F05 05
00
∫
99
Within the “Auto Zero” range, weighing part is steady, indicator will
display current weight as “Zero”
If the weighing part is not “Steady”, indicator will display current weight.
(Auto Zero Range : ± Set value + weight unit)
※
Using this function, you can get the Zero value without pressing “Zero” key, when there is remained
material on the scale within Auto Zero Range.
Example) Max. Capacity : 10kg, Digit : 0.02kg, F005-30 setting,
Under this setting, Indicator will display “Zero” automatically, when the weight is within ± 0.30kg(Set
value + weight unit) and Steady.
Motion Band Range
Steady
Range
F03-01
Motion Band Range
Zero
F03-01
+0.30kg
-0.30kg
about 5msec.
0.075kg
(1.5
ⅹ
digit)
Display Zero
Display Current weight
Zero breaks
Weight
time