Manual Discharge selection (Under F21-04, 05, 06, 07 setting)
●
0
Manual Discharge Not Use.
F28
1
Manual Discharge Use.
(If you press “F” + “RUN/STOP” key, discharge gate will be open
during 5sec.)
※
Under Loss-In weight Mode(F21-02, 04~07), and Packer Mode setting.
If you press Manual Discharge function, all feeding gate will be open during 5sec, and LED display will
blink and inform to operators about “Manual Discharging operation”.
PRE1 Relay “ON” range selection (Under F21-04, 05, 06 setting)
0
When PRE1 set value is under 120% of FINAL value, SP1 relay OFF
1
When PRE1 set value is under 110% of FINAL value, SP1 relay OFF
2
When PRE1 set value is under 105% of FINAL value, SP1 relay OFF
●
3
When PRE1 set value is under 100% of FINAL value, SP1 relay OFF
4
When PRE1 set value is under 95% of FINAL value, SP1 relay OFF
5
When PRE1 set value is under 90% of FINAL value, SP1 relay OFF
6
When PRE1 set value is under 85% of FINAL value, SP1 relay OFF
7
When PRE1 set value is under 80% of FINAL value, SP1 relay OFF
8
When PRE1 set value is under 75% of FINAL value, SP1 relay OFF
F29
9
When PRE1 set value is under 70% of FINAL value, SP1 relay OFF
※
Under Loss-in weight Mode2, 3, 4, Feeding start time will be determined by SP1 relay.
Example 1.)
FINAL
set value is 1,000kg,
F29-03
setting,
When there is only 1,000kg in the feeding hopper, the PRE 1 relay will not be OFF, and you can start
additional weighing process.
But, at the same condition, if there is only 995kg in the feeding hopper, the SP1 relay will be OFF,
and you can not start additional weighing process.
If you want to start additional weighing, please change the F29 setting as large set value than 03.
After finishing all the process, you want to discharge remained material, please use “Manual