- 40 -
Weighing Mode 1. Limit Mode (F21
◆
-01 setting) - No Finish Relay output.
1. Set value setting
FINAL(Target weight), PRE 1(Bulk), PRE 2(Drib), FREE FALL(Fall)
Setting conditions : (PRE 1 > PRE 2)
, (
PRE 1 < FINAL - FREE FALL)
※
If the setting conditions are not satisfied,
“E”
symbol displayed and you can process the weighing.
2. Low / High output (LOW/HIGH value must be smaller than Max. Capacity.)
Under relay output : Relay output, when the current weight is less than (FINAL-LOW) value.
Over relay output : Relay output, when the current weight is more than (FINAL+HIGH) value.
3. Output Relay
Relay
Contents
Relay
Contents
PRE1
Current weight = PRE 1 (ON)
Low
Current weight < FINAL-LOW (ON)
PRE2
Current weight=PRE2(ON)
High
Current weight > FINAL+HIGH (ON)
FINAL
Current weight=FINAL(ON)
Near Zero
Within “EMPTY” range (ON)
※
This Flow chart was made based on
“LOW/HIGH” set value is “0”
PRE 1
PRE 2
FINAL
Weight
Near Zero
TARE input
PRE 1
PRE 2
FINAL
LOW
HIGH
Near Zero
Output1
Output2
Output3
Output4
Output5
Output6