- 31 -
※
Caution
Under this setting,
“
Saved data
”
and
“
Printed data
”
is same. So, this setting is recommended for
Automatic weighing process.
5. F01-02, F38-00 setting (Combined Save mode(Auto + manual save mode) + manual print mode
When
“
Finish relay
”
output, finished data will be saved automatically, but same data will not be printed.
And also, if there is additional
key input, weighing data will be saved once again and printed
out.
※
Caution
After
“
Finish relay
”
output, if there is additional
key input, indicator will save two different
data for single process.
6. F01-02, F38-01 setting (Combined Save mode(Auto + manual save mode) + Auto print mode)
When “Finish relay” output, finished data will be saved and printed automatically.
But, if there is additional
key input, weighing data will be saved once again.
※
Caution
After
“
Finish relay
”
output, if there is additional
key input, indicator will save two different
data for single process.
Weight-Back up selection
●
0
Normal
Mode
F02
1
Weight Back up Mode
Normal Mode
※
When the power is off , “Zero value” will be out and will display wrong weight value after power is
recovered.
Also, if there is material over 10% of max. capacity weight, the
“Un-Pass”
display will be appear and
you can not process weighing job.
If there is material less than 10% of max. capacity weight on the scale, indicator will initialize
with
”Pass”
display, and display
“0”
whatever the real weight is. Under this case, remove the material
and press
“Zero”
key and input new
“Zero”
value. Then, new Zero value will be memorized and you
can process weighing job.