- 45 -
Weighing Mode 6. Loss
◆
-in Weight 3. - Finish / Error Relay output
1. Set value setting
FINAL(Discharge Target), PRE 1(Bulk), PRE 2(Feeding Target), FREE FALL(Bulk discharge)
Setting conditions : (PRE 2
≥
PRE 1), (PRE1
≥
FINAL - Free Fall)
※
If the setting conditions are not satisfied,
“E”
symbol displayed and you can process the weighing.
2. Automatic Free Fall Compensation Function available : F-Function 20
3. Weighing Start : RUN key input
Æ
Auto TARE, weighing start, After Finish
Æ
automatic TARE RESET
4. Manual Discharge : If the remained material is under “F29 set range”, you can discharge with
“F+RUN/STOP” key input.
5. Finish relay output delay time(t1) setting : F-Function 22
6. Finish relay output “ON” time(t2) setting : F-Function 23
7. Error relay output “ON” time(t4) setting : F-Function 28
※
LOW/HIGH value must be smaller than Max. Capacity
8. Relay Output
Relay
Contents
Relay
Contents
PRE1
Current weight=PRE 1(ON)
Under “F29 set range”(OFF)
Near Zero
Within “EMPTY range” (ON)
PRE2
Current weight=PRE 2(ON)
Current weight<PRE 2(OFF)
Error
After “t1” time,
during “t4” time(ON)
FINAL
RUN key input (ON)
Current weight=FINAL(OFF)
Finish
After “t1” time,
During “t2” time(ON)
FALL
Weight
Near Zero
TARE Input
PRE 1
PRE 2
FINAL
FINISH
ERROR
Near Zero
TARE Reset
START
PRE 1
PRE 2
LOW
PASS
HIGH
t 1
FINAL
FINAL Set
t 2
t 4
Output 6
Output 1
Output 2
Output 3
Output 4
Output 5