![Sesamo PROSWING R Manual Instructions Download Page 25](http://html1.mh-extra.com/html/sesamo/proswing-r/proswing-r_manual-instructions_1247165025.webp)
25
SESAMO
PROSWING
INTER LOCK WIRING AND USE
Proswing control board can work in inter lock with another Proswing board. Inter lock means
that it is possible to open/close only one door at a time. To connect two boards proceed as
follow (Fig. 35):
• connect “board with priority” AUX IN 1 to “board without priority” AUX OUT 1
-A
• connect “board with priority” COM to “board without priority” AUX OUT 1
-B
• connect “board with priority” AUX OUT 1
-
A to “board without priority” AUX IN 1
• connect “board with priority” AUX OUT 1
-
B to “board without priority” COM.
Use 4x0,22 shielded cable, do not connect shield.
Set priority for opening in case of simultaneous command through parameters 15 and 17:
• set parameter 15 =2 on “board with priority”;
• set parameter 17 =1on “board with priority”;
• set parameter 15 =3 on “board without priority”;
• set parameter 17 =1 on “board without priority”.
In this way in case of simultaneous command will open Master as a first door.
ATTENTION: In case of inter lock wiring between two double Proswing the wiring has to
be made between the two master boards, whereas one of the two will be considered with
priority and the other without priority to the interlock functioning..
ATTENTION: Disconnect jumper near AUX OUT-1 both on board with priority and board
without priority (Fig.29).
one
LOGIC SWITCH
In addition to base or advanced selectors there is a switch selector.
This switch selector is directly wired to control board and allows three logics:
I
Manual (Proswing S) or Stop Closed (Proswing M)
0
Automatic (Two Radars)
II
Stop Open
If Base or Advanced selector is connected, switch selector is excluded.
CONNECTOR FOR PC
–
UNIT CONNECTIONS
For PC connection board (optional) is required to connect the PROSWING unit to a Personal
Computer. The following is possible with MILLENNIUM WARE software:
•
Advanced adjustments of some operating parameters
•
Diagnostic and advanced information on status
•
Microprocessor programming
DELIVERY MODALITY
Close the automatism cover and tight screws.
Hand the guarantee and test certificate over filled according to the instructions shown in the
certificate. The certificates must be sent to SESAMO in 8 days from the positive test date.
Hand the technical documentations over to the client .
Summary of Contents for PROSWING R
Page 1: ...P R O S W I N G R ENGLISH OPERATOR FOR SWINGING DOORS MANUAL INSTRUCTIONS...
Page 2: ......
Page 26: ...26 SESAMO PROSWING...
Page 27: ...27 SESAMO PROSWING Fig 1 Fig 2 Fig 3...
Page 28: ...28 SESAMO PROSWING Fig 4...
Page 29: ...29 SESAMO PROSWING Fig 5...
Page 30: ...30 SESAMO PROSWING Fig 6...
Page 31: ...31 SESAMO PROSWING Fig 7...
Page 32: ...32 SESAMO PROSWING Fig 8...
Page 33: ...33 SESAMO PROSWING Fig 9 Fig 10...
Page 34: ...34 SESAMO PROSWING Fig 11 Fig 12...
Page 35: ...35 SESAMO PROSWING Fig 13 Fig 14 Fig 15 Fig 16...
Page 36: ...36 SESAMO PROSWING Fig 17 Fig 18 m Kg...
Page 37: ...37 SESAMO PROSWING Fig 19...
Page 38: ...38 SESAMO PROSWING Fig 20 Fig 21...
Page 39: ...39 SESAMO PROSWING Fig 22...
Page 40: ...40 SESAMO PROSWING Fig 23...
Page 41: ...41 SESAMO PROSWING Fig 24 Fig 25...
Page 42: ...42 SESAMO PROSWING Fig 26 Fig 27...
Page 43: ...43 SESAMO PROSWING Fig 28 Fig 29...
Page 44: ...44 SESAMO PROSWING Fig 30 Fig 30...
Page 45: ...45 SESAMO PROSWING Fig 31...
Page 46: ...46 SESAMO PROSWING...
Page 47: ......