Sesamo PROSWING R Manual Instructions Download Page 20

 

20 
 

SESAMO

 

PROSWING

 

CL Fixed 

Door closed 

CL Blinking 

Door closing 

E1 

Door needs self learning procedure (see Paragraph “Start up”)

 

E2 

Wrong arm selection [DIP 1 or switch on break board - see Paragraph 

“type arm selection”),  or

 wrong selection automatism- DIP 5. 

E3/E4 

Over Current 

E6 

Error  monitored sensors  

E8 

NO encoder 

 

OPERATING LOGICS

 

 

LOGICA

 

DESCRIZIONE

 

LOW-ENERGY 

In all operative procedures (except Stop Close) it is possible a motor 
opening with a reduced speed (Low Energy speed) and higher idle 
time (idle time for disabled people) using the opening command for 
disabled [AUX IN 1set through parameters 15=0  paragraph 

“Parameter adjustment display”. The following closing is by spring. 

 

PUSH & GO 

An opening/closing automatic movement is possible slightly  pushing 
door in opening by  hand while it is in a closed position. Set DIP 3 = 
ON. 

SAFE CLOSE 

If closing safety sensor detects an obstacle whilst the door is closing, 
it immediately stops and opens door completely . 
If sensor detects while door is  opening door continues opening. 

SAFE OPEN 

If opening safety sensor detects an obstacle whilst door is opening, it 
immediately stops door movement. When detection stops, door 
continues to open and then close. 
If sensor detects while door is  closing door continues closing. 
If door opens toward a wall (in a corridor, for example) it is possible 
to cancel the final part sensor detection to avoid wall detection. This 
parameter is modifiable through parameter 20 (see paragraph 

“Parameter adjustment display”).  

 

Logic switch, 
basic selector, 
advanced 
selector 
operating logic 

Manual 

START 1 and START 2 are not working. Open and close only through 
push button on selector or low energy or manually pushing the door. 

1 radar 

RADAR  ONLY EXIT: Only START 2 input is working. A signal coming 
from a sensor connected to START2 makes opening and closing of 
the door. If the door is blocked by a lock or by motor (when no lock is 
selected),  the closing position depends on the type of lock or the 
setting of parameter 14. 

2 radar 

RADAR ENTRY AND EXIT (Automatic): Both input START1 e START2 
are working. A signal coming from a sensor connected to one of 
these two inputs makes the opening and closing of the door. The 
door blocked by lock or motor (when no lock is selected),  the closing 
position depends on the type of lock or the setting of parameter 14. 

Stop 
close 

Automatism sends door in fully closed position. In this logic the 
inputs START1 and START2 of the electronic control card are not 
working; if installed, electric locking system locks door. When there 

Summary of Contents for PROSWING R

Page 1: ...P R O S W I N G R ENGLISH OPERATOR FOR SWINGING DOORS MANUAL INSTRUCTIONS...

Page 2: ......

Page 3: ...All automatic entrance safety and protection devices photocells active sensors etc must be installed in accordance with the regulations and directives in force with the completed risk analysis system...

Page 4: ...Declares that the product PROSWING R is made to be incorporated in a machine to construct a machine considered by Directive 2006 42 CE conforms with the essential safety requirements indicated in app...

Page 5: ...N16005 reduced dynamic force low speed reduced dynamic static force It is installer s responsibility to verify the compliance of the installation Low Energy compared with current standards The protect...

Page 6: ...ion manual is not allowed 18 This operating instructions manual is only intended for qualified personnel 19 It is mandatory to use a MAG LOCK to keep the door in closed position RECYCLING AND DISPOSAL...

Page 7: ...lation PRELIMINARY CHECKS Before installing the automatism please check verify the installation does not create dangerous situations prearrange proper pipes and conduits for the wires granting the pro...

Page 8: ...closing cycle A positioning error of the automatism might create bending between the bolt of the pulling arm and the cylindrical skid more than the allowed tolerance damaging parts of the automatism...

Page 9: ...A Fix the first part of the articulated push arm Fig 11 part D in the slot of the arm extension as indicated in Fig 11 and tight screws Fig 11 part E ATTENTION THE MAX TORQUE TO BE USED TO TIGHTEN SC...

Page 10: ...vice using qualified technicians For maintenance please have a look on the manual BREAKE ADJUSTEMENT WITHOUT POWER Set breaking level on terminal board Fig 30 to suit closing speed without power suppl...

Page 11: ...board A Expansion connector for additional board Optional B Display and buttons C Dip switches D PC connector E Transformer connector F Batteries connector G Switch ON OFF connector H Logics switch c...

Page 12: ...SAFE OPEN NC Opening safety contact for safety sensors monitoring opening cycle If the door is opening and the contact opens the control board gives a stop command immediately Opening will only conti...

Page 13: ...ows 0 Monitoring sensors It monitors safety sensors 1 Inter lock To be connected to the input interlock of the other automatism to obtain interlock logic 2 Door opened It signals door in opened positi...

Page 14: ...s wired or the sensors connected will be managed as a normal sensors without monitoring S1 monitored sensor only in opening There is only monitored sensor in opening In closing there is no sensor conn...

Page 15: ...ing is working again DIP SWITCHES SETTING On the control board there is a dip switch 8 positions to adjust functionality and basic options ON OFF These settings are set and memorized duringt reset of...

Page 16: ...s 40 s step of 5 s 20 03 Idle time RANGE 0 60 seconds 62 2 min 63 3 min 64 4 min 0 04 Idle time in Low Energy RANGE 5 60 seconds adjustment step of 1 second 5 05 Closing speed with spring PROSWING S...

Page 17: ...oor 7 Stand by 8 Reactivate the door after stand by 9 step step function 1 impulse open 1 impulse close 1 17 Auxiliary output configuration 1 0 Sensors monitoring 1 Interlock 2 Stop open condition 3 S...

Page 18: ...Low Energy 1 speed according to parameters 1 e 2 0 36 Batteries mode 0 std only spring 1 continuos operation 2 antipanic 0 ST Stop movement TS Test 0 no cyclical 1 cyclical 2 intensive cyclical 0 LS...

Page 19: ...ameters adjustment display and or electric locks setting 7 Pushing buttons e select LP and push ENT when it shows push again ENT for 5 seconds to confirm the commend when disappears release push butto...

Page 20: ...continues to open and then close If sensor detects while door is closing door continues closing If door opens toward a wall in a corridor for example it is possible to cancel the final part sensor det...

Page 21: ...nical relock on closing 2 Maglock only24Vdc 3 Magnetic bolt 4 Motorized 5 Impulsive with relock at power off 6 Magnetic with delayed relock only24Vdc 2 11 Opening delay 3 RANGE 0 9 Time depends on the...

Page 22: ...oard waits for confirmation before starting opening cycle If this sign does not reach the control board in a maximum determined time automatism opens the door anyway 7 It is possible to use one of the...

Page 23: ...minum base and the central joining base on a plane surface 3 insert each base under the lug nut of the two joining parts as showed Fig 30 ATTENTION Maintain the orientation of the aluminum bases as sh...

Page 24: ...ely after it starts opening the SLAVE door and even for this door it is necessary to stop the door in the max opening desired point After this operation the doors will both start closing cycle CL on d...

Page 25: ...has to be made between the two master boards whereas one of the two will be considered with priority and the other without priority to the interlock functioning ATTENTION Disconnect jumper near AUX OU...

Page 26: ...26 SESAMO PROSWING...

Page 27: ...27 SESAMO PROSWING Fig 1 Fig 2 Fig 3...

Page 28: ...28 SESAMO PROSWING Fig 4...

Page 29: ...29 SESAMO PROSWING Fig 5...

Page 30: ...30 SESAMO PROSWING Fig 6...

Page 31: ...31 SESAMO PROSWING Fig 7...

Page 32: ...32 SESAMO PROSWING Fig 8...

Page 33: ...33 SESAMO PROSWING Fig 9 Fig 10...

Page 34: ...34 SESAMO PROSWING Fig 11 Fig 12...

Page 35: ...35 SESAMO PROSWING Fig 13 Fig 14 Fig 15 Fig 16...

Page 36: ...36 SESAMO PROSWING Fig 17 Fig 18 m Kg...

Page 37: ...37 SESAMO PROSWING Fig 19...

Page 38: ...38 SESAMO PROSWING Fig 20 Fig 21...

Page 39: ...39 SESAMO PROSWING Fig 22...

Page 40: ...40 SESAMO PROSWING Fig 23...

Page 41: ...41 SESAMO PROSWING Fig 24 Fig 25...

Page 42: ...42 SESAMO PROSWING Fig 26 Fig 27...

Page 43: ...43 SESAMO PROSWING Fig 28 Fig 29...

Page 44: ...44 SESAMO PROSWING Fig 30 Fig 30...

Page 45: ...45 SESAMO PROSWING Fig 31...

Page 46: ...46 SESAMO PROSWING...

Page 47: ......

Page 48: ...SESAMO srl Str Gabannone 8 10 15030 Terruggia AL Italy Tel 39 0142 403223 Fax 39 0142 403256 www sesamo eu e mail info sesamo eu MAN_PRO R _EN_16_10_20...

Reviews: