20
SESAMO
PROSWING
CL Fixed
Door closed
CL Blinking
Door closing
E1
Door needs self learning procedure (see Paragraph “Start up”)
E2
Wrong arm selection [DIP 1 or switch on break board - see Paragraph
“type arm selection”), or
wrong selection automatism- DIP 5.
E3/E4
Over Current
E6
Error monitored sensors
E8
NO encoder
OPERATING LOGICS
LOGICA
DESCRIZIONE
LOW-ENERGY
In all operative procedures (except Stop Close) it is possible a motor
opening with a reduced speed (Low Energy speed) and higher idle
time (idle time for disabled people) using the opening command for
disabled [AUX IN 1set through parameters 15=0 paragraph
“Parameter adjustment display”. The following closing is by spring.
PUSH & GO
An opening/closing automatic movement is possible slightly pushing
door in opening by hand while it is in a closed position. Set DIP 3 =
ON.
SAFE CLOSE
If closing safety sensor detects an obstacle whilst the door is closing,
it immediately stops and opens door completely .
If sensor detects while door is opening door continues opening.
SAFE OPEN
If opening safety sensor detects an obstacle whilst door is opening, it
immediately stops door movement. When detection stops, door
continues to open and then close.
If sensor detects while door is closing door continues closing.
If door opens toward a wall (in a corridor, for example) it is possible
to cancel the final part sensor detection to avoid wall detection. This
parameter is modifiable through parameter 20 (see paragraph
“Parameter adjustment display”).
Logic switch,
basic selector,
advanced
selector
operating logic
Manual
START 1 and START 2 are not working. Open and close only through
push button on selector or low energy or manually pushing the door.
1 radar
RADAR ONLY EXIT: Only START 2 input is working. A signal coming
from a sensor connected to START2 makes opening and closing of
the door. If the door is blocked by a lock or by motor (when no lock is
selected), the closing position depends on the type of lock or the
setting of parameter 14.
2 radar
RADAR ENTRY AND EXIT (Automatic): Both input START1 e START2
are working. A signal coming from a sensor connected to one of
these two inputs makes the opening and closing of the door. The
door blocked by lock or motor (when no lock is selected), the closing
position depends on the type of lock or the setting of parameter 14.
Stop
close
Automatism sends door in fully closed position. In this logic the
inputs START1 and START2 of the electronic control card are not
working; if installed, electric locking system locks door. When there
Summary of Contents for PROSWING R
Page 1: ...P R O S W I N G R ENGLISH OPERATOR FOR SWINGING DOORS MANUAL INSTRUCTIONS...
Page 2: ......
Page 26: ...26 SESAMO PROSWING...
Page 27: ...27 SESAMO PROSWING Fig 1 Fig 2 Fig 3...
Page 28: ...28 SESAMO PROSWING Fig 4...
Page 29: ...29 SESAMO PROSWING Fig 5...
Page 30: ...30 SESAMO PROSWING Fig 6...
Page 31: ...31 SESAMO PROSWING Fig 7...
Page 32: ...32 SESAMO PROSWING Fig 8...
Page 33: ...33 SESAMO PROSWING Fig 9 Fig 10...
Page 34: ...34 SESAMO PROSWING Fig 11 Fig 12...
Page 35: ...35 SESAMO PROSWING Fig 13 Fig 14 Fig 15 Fig 16...
Page 36: ...36 SESAMO PROSWING Fig 17 Fig 18 m Kg...
Page 37: ...37 SESAMO PROSWING Fig 19...
Page 38: ...38 SESAMO PROSWING Fig 20 Fig 21...
Page 39: ...39 SESAMO PROSWING Fig 22...
Page 40: ...40 SESAMO PROSWING Fig 23...
Page 41: ...41 SESAMO PROSWING Fig 24 Fig 25...
Page 42: ...42 SESAMO PROSWING Fig 26 Fig 27...
Page 43: ...43 SESAMO PROSWING Fig 28 Fig 29...
Page 44: ...44 SESAMO PROSWING Fig 30 Fig 30...
Page 45: ...45 SESAMO PROSWING Fig 31...
Page 46: ...46 SESAMO PROSWING...
Page 47: ......