10
SESAMO
PROSWING
ATTENTION: For articulated push arm, both right/left opening, set switch as shown
in Fig. 16.
SPRING ADJUSTMENT
The spring has to be charged according to the width of the door keeping in consideration the
norm EN 1154 in the range from EN 4 to EN 6.
Range of adjustment can be obtained from diagram in Fig.17 according to the width and
weight of the door, both for pull or push arm. During spring adjustment, wind force, over-
pressure and other environmental condition that might open the door, must be considered.
Adjust force of the spring tightening the screw (Fig. 12, Part.A) in order to tension the spring
up to the end of the plate (Fig. 12 part. B) on the range requested for the type of installation
(class EN identified).
ATTENTION: Keep in consideration the spring is a component that, when at maximum
compression, accumulates very high energy, it is necessary that both the spring both the
related components would be only replaced by using ORIGINAL parts. It is also recommended
to program service using qualified technicians. For maintenance please have a look on the
manual.
BREAKE ADJUSTEMENT WITHOUT POWER
Set breaking level on terminal board (Fig. 30) to suit closing speed without power supply to
door width/weight, ref. to Fig.16. Verify functionality opening door by hand and checking
closing cycle with spring, without power.
PRELIMINARY CHECKING
Before electrical wiring, check as follows:
-
Remove carefully dust or any other residual of the installation
-
Verify automatism being well fixed
-
Verify all screws well tighten
-
Verify all wiring well fixed and not near moving parts
-
Verify arm well fixed to door.
-
Verify arm well fixation of the plastic end side caps to the aluminium base
ATTE ATTENTION: ensure that the spring protection bracket is fixed (Fig.12, part. C) and
that the label with the seal hasn’t been removed
(Fig.12, part. D).
WIRING POWER SUPPLY
ATTENTION: Wiring the connectors of the control panel or external peripheral
connections must be in absence of power supply in order to avoid irreversible damages of the
electronic device.
ATTENTION: before performing the following operation make sure the power supply is
OFF. Before starting the automatism, check and perform as paragraph “Start up”.
Summary of Contents for PROSWING R
Page 1: ...P R O S W I N G R ENGLISH OPERATOR FOR SWINGING DOORS MANUAL INSTRUCTIONS...
Page 2: ......
Page 26: ...26 SESAMO PROSWING...
Page 27: ...27 SESAMO PROSWING Fig 1 Fig 2 Fig 3...
Page 28: ...28 SESAMO PROSWING Fig 4...
Page 29: ...29 SESAMO PROSWING Fig 5...
Page 30: ...30 SESAMO PROSWING Fig 6...
Page 31: ...31 SESAMO PROSWING Fig 7...
Page 32: ...32 SESAMO PROSWING Fig 8...
Page 33: ...33 SESAMO PROSWING Fig 9 Fig 10...
Page 34: ...34 SESAMO PROSWING Fig 11 Fig 12...
Page 35: ...35 SESAMO PROSWING Fig 13 Fig 14 Fig 15 Fig 16...
Page 36: ...36 SESAMO PROSWING Fig 17 Fig 18 m Kg...
Page 37: ...37 SESAMO PROSWING Fig 19...
Page 38: ...38 SESAMO PROSWING Fig 20 Fig 21...
Page 39: ...39 SESAMO PROSWING Fig 22...
Page 40: ...40 SESAMO PROSWING Fig 23...
Page 41: ...41 SESAMO PROSWING Fig 24 Fig 25...
Page 42: ...42 SESAMO PROSWING Fig 26 Fig 27...
Page 43: ...43 SESAMO PROSWING Fig 28 Fig 29...
Page 44: ...44 SESAMO PROSWING Fig 30 Fig 30...
Page 45: ...45 SESAMO PROSWING Fig 31...
Page 46: ...46 SESAMO PROSWING...
Page 47: ......