14
SESAMO
PROSWING
Sensors wiring and control board setting:
ID
SENSORE
SCHEMA
17=0
30=1
Safety monitoring sensor in closing (ref. Fig.39 A)
ref. Fig.22
17=0
30=1
Safety monitoring sensor in opening (ref. 39 B)
ref. Fig.23
Detection sensor (radar) entry (ref. Fig.39 D)
ref. Fig.24
Detection sensor (radar) exit (ref. Fig.39 C)
ref. Fig.25
If monitored sensors configuration has not been memorized, on display appears E6 error. Exit
fr
om this status through procedure LS, see paragraph “parameters adjustment –
display”.
During this procedure control board checks which sensors are connected and checks if they
are correctly working.
ATTENTION during LS procedure stay away from sensors and be sure they are not
detecting obstacles. In case they are not correctly wired or working, LS blinks. Abort procedure
pushing ESC. Checks sensors and launch LS again.
At the end of LS procedure display shows one of the following configurations:
ID
CONFIGURATION
DESCRIPTION
S0
No monitored sensor
detected
There are no monitored sensors wired or the sensors
connected will be managed as a normal sensors without
monitoring.
S1
monitored sensor only in
opening.
There is only monitored sensor in opening. In closing there
is no sensor connected or the sensor connected will be
managed as a normal sensor without monitoring.
S2
monitored sensor only in
closing.
There is only monitored sensor in closing. In opening , there
is no sensor connected or the sensor connected will be
managed as a normal sensors without monitoring.
S3
monitored sensor in
opening and closing.
There are monitored sensors wired both in closing and
opening.
The indication remains on the display until it is pressed one of the following push buttons:
-
ENT: to confirm the configuration indicated, making sure that it correspond to the
real configuration of the connected sensors;
-
ESC: to abort the detected configuration and go back to the error status E6.
ATTENTION: never confirm the detected configuration if does not correspond to the
real configuration of the connected sensors. This might create danger situations or
malfunction of the automatism.
LS procedure can be repeated in any occasion through the parameter LS (look at
paragraph “parameters adjustment –
display”
).
Summary of Contents for PROSWING R
Page 1: ...P R O S W I N G R ENGLISH OPERATOR FOR SWINGING DOORS MANUAL INSTRUCTIONS...
Page 2: ......
Page 26: ...26 SESAMO PROSWING...
Page 27: ...27 SESAMO PROSWING Fig 1 Fig 2 Fig 3...
Page 28: ...28 SESAMO PROSWING Fig 4...
Page 29: ...29 SESAMO PROSWING Fig 5...
Page 30: ...30 SESAMO PROSWING Fig 6...
Page 31: ...31 SESAMO PROSWING Fig 7...
Page 32: ...32 SESAMO PROSWING Fig 8...
Page 33: ...33 SESAMO PROSWING Fig 9 Fig 10...
Page 34: ...34 SESAMO PROSWING Fig 11 Fig 12...
Page 35: ...35 SESAMO PROSWING Fig 13 Fig 14 Fig 15 Fig 16...
Page 36: ...36 SESAMO PROSWING Fig 17 Fig 18 m Kg...
Page 37: ...37 SESAMO PROSWING Fig 19...
Page 38: ...38 SESAMO PROSWING Fig 20 Fig 21...
Page 39: ...39 SESAMO PROSWING Fig 22...
Page 40: ...40 SESAMO PROSWING Fig 23...
Page 41: ...41 SESAMO PROSWING Fig 24 Fig 25...
Page 42: ...42 SESAMO PROSWING Fig 26 Fig 27...
Page 43: ...43 SESAMO PROSWING Fig 28 Fig 29...
Page 44: ...44 SESAMO PROSWING Fig 30 Fig 30...
Page 45: ...45 SESAMO PROSWING Fig 31...
Page 46: ...46 SESAMO PROSWING...
Page 47: ......