1.2
Scope parameters
Scope parameters :
5 parameters for scope settings (Address 41..45).
80 read only parameters for the measuring values (Address 100..179).
Use of scope function
When a time scale different of 0 is written, the drive starts the measurement, the parameters
100..179 are filled cyclically with samples.
When trigger condition is satisfied, the drive saves the position (trigger position parameter) and
continues the measurement during the number of post-trig samples defined. At the end of the
measurements, time scale parameter is set to 0 to indicate the end.
Add
Description
Comment
41
Time scale
Factor of 133 us for the sampling time.
42
HB Parameter 1 address (channel 1)
Address of parameter 1 to measure
LB
Parameter 1 scale
Number of shift (left shift for positive
value and right shift for negative value)
43
HB Parameter 2 address (channel 2)
Address of parameter 2 to measure
LB
Parameter 2 scale
Number of shift (left shift for positive
value and right shift for negative value
44
HB Slope positive/negative or null
null for no trigger
LB
Trigger value
Threshold value
45
HB Trigger position
Address where the trig point is (100..179)
LB
Number of Post-trig samples
0 : 100 % pretrig
80 : 0 % pretrig
46
Scope options
(since firmware
V2005)
bit 15 = 0 -+ saturation (when values overshoot with the defined
scale).
bit 15 = 1 -+ no saturation (for bit wise operations or low bits
watching)
100 HB Value 1 of parameter 1
Measured value
LB
Value 1 of parameter 2
Measured value
..
179 HB Value 80 of parameter 1
Measured value
LB
Value 80 of parameter 2
Measured value