Chapter D - Setting to work
Rev. A 10-99
DigiDrive Manual Series 2000 / 4000
Pg 71
Servo Dynamics Corp. 21541-D Nordhoff St. Chatsworth, CA 91311 www.servodynamics.com
Display
Trouble shooting
Parameter not OK (wrong checksum of stored parameter)
Check parameter and store parameters.
Firmware not OK (only after an update of the firmware)
Reload firmware.
blinking
Hardware incompatibility.
The firmware is incompatible with drive hardware.
Trouble
Possible cause
Display 0 but the motor doesn’t move
when a speed command is applied
End-limit switch enable
Max. drive current too low (P3)
Motor brake engaged
The motor jump to a position and stay
blocked.
Pair of motor Poles parameter (P0) misadjusted.
Motor wiring on terminal U, V, W not in the correct
sequence.
Motor noisy
Check resolver cable
Check separation between resolver and motor
cable (also inside the motor).
Check earth link
Check regulation parameters.
No link with Drive (Drive Offline
appears in User software while the
drive is connected to the computer).
Check
A
XIS SELECTOR
position (if present) :
RS232 : Position 0
RS485 : Position 1-15
The drive must be resetted to enable a change of
the Axis selector position (for more information
about Axis selector, see page 43).
Check link cable.
Check Serial Port number in User software.
Firmware upgrade cannot be
performed.
The firmware upgrade is possible only with
RS232 link.
Check RS232 link
Summary of Contents for DigiDrive 2000 Series
Page 2: ...www servodynamics com...