DA
L
19
65
Page 14/18
With the control unit powered and the gate closes, press key A once (SET) to enter programming. The DL10
LED starts to flash to indicate that the control unit is in the programming state.
While the leaf is opening, regulate the power of the motor by intervening on the POWER potentiometer.
: - If the POWER potentiometer is regulated too low, the gate cannot open. We
recommend that the POWER is regulated starting from MAXIMUM and gradually
dropping to minimum.
ATTENTION
- The large temperature differences between the summer and winter cause
different dilation of materials, including those with which the motors are built.
For this reason it is recommended to control the regulation of the motor thrust at
the start of the winter and the summer.
ATTENTION: - If one or more parameters are varied, programming must be repeated from
the beginning.
- In the programming procedure, slowing has only been set in the closure
phase, but in normal functioning mode it is also introduced in the opening
phase.
Press key C (WORK) once to start the opening phase of motor (M1).
When the leaf is against the opening stop, wait a few seconds (3-4s max) and then press key C (WORK) once.
The motor (M1) is switched off.
When the leaf is completely open and the motor is not powered, press the key C (WORK) once to start the
closure phase.
When motor (M1) should start slowing (we recommend at least 50cm before the stop) press key C (WORK).
The motor (M1) slows down.
ATTENTION: jump this point id slowing has been excluded (DIP2 SW2 ON)
When the leaf is against the closing stop, wait at least 5 seconds and then press key C (WORK) once. The
motor (M1) is switched off and the control unit exits automatically from the programming phase and is ready for
normal functioning.
PROGRAMMING OPEN GATE PAUSE TIME (AUTOMATIC RE-CLOSURE)
With the control unit powered and the gate closes, press key A once (SET) to enter programming. LED
DL10 starts to flash, indicating that the board has entered the programming phase.
Press key B (BREAK) once -until the flashing light switches on-, the control unit starts the gate open pause
count, highlighted with the intermittence of flashing.
When the desired time has passed, press key B (BREAK) again, the control unit automatically memorises
the time passed between the two times the key B (BREAK) was pressed and leaves programming, going
back to normal functioning.
If key B (BREAK) is not pressed a second time, after 120s the control unit escapes from the programming
memorising the max time of 120s.
ACTIVATE AUTOMATIC RE-CLOSURE (maximum time that can be set 120s)
Press and hold key B (BREAK) until LED DL10 switches off.
The control unit leaves the programming phase and sets itself for normal functioning.
Automatic re-closure is deactivated in this way.
DEACTIVATE AUTOMATIC RE-CLOSURE
With the control unit powered and the gate closes, press key A once (SET) to enter programming. LED
DL10 starts to flash, indicating that the board has entered the programming phase.
PROGRAMMING WORK TIMES AND SLOWING FOR GATE WITH SINGLE LEAF (DIP1 SW1 ON)
K
IT
/A
9
I