CONDENSER ALREADY
WIRED INTERNALLY
!
EARTH CONNECTION BETWEEN MOTOR AND HOUSE PLANT
MOTORS OF THE
YELLOW-GREEN
CABLESI
CONNECTION CLAMP
230 V~POWER
SUPPLY CABLE
MOTOR 2
CABLE
MOTOR 1
CABLE
HOUSE PLANT
YELLOW-GREEN CABLE
MOTOR ELECTRIC CONNECTIONS
Connect the motors to the electronic control unit using cables with
section of 1.5 mm². Respect the clamps as follows:
COM
: Common
A/C
: Open/Close - Condenser
A/C:
: Open/Close - Condenser
: Earth
The following prescription must be respected (IEC 64-8):
- Connect the motors earth (yellow-green cable) to an efficient
earth plant.
- Install an omnipolar switch upstream from the plant with an ope-
ning distance of 3 mm or more between the contacts.
|
__
_
_
|
__
_
_
COM A/C A/C 1 2 3
HOLE FOR CABLE
INPUT
CABLE FIXING
CLAMP
!
Also remember that the large
temperature differences between the
summer and winter cause different
dilation of materials, including those with
which the motors are built. For this
reason it is recommended to control the
regulation of the motor thrust at the start
of the winter and the summer.
F1F1
F2
F2
ON
SW1
SW2
3 4 5 6 7 8
S
O
G
/4
POWER
+
-
ON
PED
START STOP FOTO FOTO AP FINE CH FINE AP
DL9
DL8
DL10
1 2
9 10
11121314 1516171819 20
21
22
27
2526
2324
2
8
2
9
SET
BREAK
WORK
A
B
C
Com
+24
spia
RX
ADJUSTMENT OF THE MOTORS STRENGTH
The SERAI CR/41 control unit allows:
A- adjustment of the motors strength by acting on the "Power" potentiometer in the control unit
B- programming of the slowing which prolongs the life of the motor avoiding the gate banging against the
mechanical stops
If slowing has been inserted, the motor has less strength and therefore the gate, if not well-done,
may stop before having completed the manoeuvre.
By excluding the slowing the gate bangs against the mechanical stops causing a, more or less, loud
noise, according to installation. Also, the internal gears are subject to greater stresses.
"POWER" POTENTIOMETER