DA
L
19
65
Page 12/18
- Sending a start control during the opening of the gate, causes
the same to stop.
- A successive start control makes the gate close.
STEP-BY-STEP
FUNCTION DEACTIVATED
D
U
R
IN
G
O
P
E
N
IN
G
- Sending a start control during gate closing cause it to stop for 2"
and the successive automatic re-opening.
- Sending a start control during opening is ignored, while during
the gate opening pause, it makes the gate close.
D
U
R
IN
G
C
L
O
S
U
R
E
2 s
start
start
start
start
D
U
R
IN
G
O
P
E
N
IN
G
D
U
R
IN
G
C
L
O
S
U
R
E
SENDING
A COMMAND
DURING GATE
MOVEMENT
SETTING
THE MICRO SWITCHES
DESCRIPTION OF THE FUNCTIONING
FUNCTIONING
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
- Sending a start control during gate closing cause it to stop for 2"
and the successive automatic re-opening.
2 s
start
STEP-BY-STEP
FUNCTION ACTIVATED
SW 2
SW 1
OPENING
PHOTOCELL
INPUT OR
SENSITIVE EDGE
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
LEDS INDICATION
LED
FINE CH
FINE AP
FOTO AP
FOTO
STOP
PED
START
ON
OFF
FUNCTION
Internal photocell
External photocell
Stop button
PEDESTRIAN button
Open/Close button
Opening Photocell free
from obstacles
Closure photocell free from
obstacles
Stop button in normal state
Pedestrian button pressed
Open/Close button pressed
Regular connection between
clamps 8-10
No jumper between clamps 8-10
Opening Photocell blocked out
(presence of an obstacle)
Closure Photocell blocked out
(presence of an obstacle)
Stop button pressed
Pedestrian button in normal state
Open/close button in normal state
DL10
Programming
Indicates the various phases of the programming
DL8
M2 motor command
Different light intensity
depending on the voltage
control of motor M2
Motor M2 not powered
DL9
M1 motor command
Different light intensity
depending on the voltage
control of motor M1
Motor M1 not powered
Regular connection between
clamps 9-10
No jumper between clamps 9-10
- Sensitive edge function activated: the input at clamp 6 both in the
opening and closing phase inverts movement by 10 cm.
- Open photocell function activated: by connecting the photocells to
clamp 6, if blacked-out in the opening phase, the gate stops, it starts
opening again as soon as the photocell is no longer engaged. If
blacked-out in the closure phase, the gate stops, re-opens as soon
as the photocell is no longer engaged.
K
IT
/A
9
I
E