DA
L
19
65
Page 11/18
SETTING OF EACH INDIVIDUAL MICRO SWITCH
SETTING
THE MICRO SWITCHES
DESCRIPTION OF THE FUNCTIONING
FUNCTIONING
- Single wing logic: just the output indicated with M1 is controlled
- Double wing logic: both outputs M1 and M2 are controlled
-M2 leaf delayed on opening-
CONFIGURATION
GATE
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
REGULATION
SLOWING
SPEED
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
- High slowing speed.
- Low slowing speed.
- Final blow activated: full power is given to the motors for 2 s at the
end of the closure cycle for better attachment of the electric lock.
- Final blow deactivated.
FINAL BLOW
IN CLOSURE
- Hammering activated: the electric lock is activated during a brief
closure phase against the stops and is deactivated after the start-
up of M1.
- Hammering deactivated: The electric lock is activated just after the
start-up of M1 and is deactivated a little after the start-up of M1.
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
ELECTRIC LOCK
HAMMERING
!
ATTENTION:
In case of varying the setting of the micro switches to make the new settings active, it is necessary
to switch the control unit off and on.
We recommend, after having adjusted the micro switches, to program the work times -see control unit
programming-.
SW1
SW2
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
PEAK ON
START-UP
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
SLOWING
SETTING
- Slowing deactivated.
- Sowing activated.
-
Peak on start-up activated: on start-up, the motors are
powered at maximum voltage for 2s.
RECOMMENDED ESPECIALLY IN THE WINTER
- Peak on start-up deactivated: on start-up, the motors are powered
at the voltage set with the potentiometer.
ATTENTION: in this case, there may be difficulties on
start-up if the force is regulated low
!
!
ATTENTION: If slowing has been inserted, the motor has less strength and therefore the gate, if
not well-done, may stop before having completed the manoeuvre.
By excluding the slowing the gate bangs against the mechanical stops causing a, more or less,
loud noise, according to installation. Also, the internal gears are subject to greater stresses.