Page 17/18
9
0
m
m
70 mm
TX
RX
h
MIN
h
MIN
h
= 40 cm
MIN
l = 10
m
MAX
l
MAX
RX
TX
TX
RX
RX
RX
TX
TX
NO
OK
PHOTOCELL TECHNICAL SPECIFICATIONS
Operating range
- outdoor ................. 10 m
- indoor ................... 20 m
Power supply ......... 24 V~ ±10%
TX absorption ........ 55 mA a 24 V-;
67 mA a 24 V~
RX absorption ........ 15 mA a 24 V-;
25 mA a 24 V~
Ø 6mm
Ø 3.5mm
P/10 PHOTOCELLS
NO
OK
RECEIVER
TRANSMITTER
POWER SUPPLY
RELAY
OUTPUT
POWER SUPPLY
ALIGNMENT
RX
TX
LED
CONNECTIONS
The cable routing hole must be sized exactly for the cable
to be passed through and no more
Relay output............ 1A 24 V~
Temperature............ -10° ÷ +60°C
Dimensions.............. 70 x 40 x 90 mm
Weight......................120 g
RX
RX
THE CONTACT POSITION
REFERS TO WHEN THE RECEIVER
IS ENERGIZED
40 mm
POSITION
DIMENSIONS
INSTALLATION
RX
SPHERICAL ORANGE LAMP WITH BUILT-IN 433.92 MHz ANTENNA - 230 V~ RZ/20 F
!
RZ/99
SR 10.99
L-SHAPED
HOLDER
NO
2 x 0.75 mm²
POWER SUPPLY
RG58
ANTENNA
CS/07 SR12.07
OPTIONAL CABLE
CONNECTIONS
!
WARNING:
WE RECOMMEND YOU POSITION THE POWER SUPPLY CABLE INSIDE A CONDUIT WHICH IS NOT ACCESSIBLE
BY THE USER.
HOWEVER, IF SOME PARTS REMAIN ACCESSIBLE, THESE MUST HAVE DOUBLE INSULATION TOWARDS THE
USER. CABLE CLAMPS MUST ALSO BE USED TO AVOID TEARING OF THE CABLE.
2
3
0
V
c
a
2
3
0
V
c
a
WHEN REPLACING LIGHT
BULBS, ALWAYS USE
230 V MIN. 25W
PEAR BULBS
SIN
CE
1
96
5
K
IT
/3
0
-3
9
F
I
E