background image

Page 12/18

STEP-STEP 

FUNCTION 
DISABLED

D

U

R

IN

G

 

O

P

E

N

IN

G

- A start command sent during closing causes the gate to stop for 

2” and subsequent automation re-opening.

- A start command sent during opening is ignored, while during the 

gate open pause causes closure.

D

U

R

IN

G

 

C

L

O

S

U

R

E

2 s

start

start

start

start

D

U

R

IN

G

 

O

P

E

N

IN

G

D

U

R

IN

G

 

C

L

O

S

U

R

E

COMMAND SENT

 DURING 

GATE MOVEMENT

MICROSWITCH

SETTINGS

DESCRIPTION OF OPERATION

OPERATION

1

2

3

ON

4

1

2

3

ON

4

1

2

3

ON

4

1

2

3

ON

4

- A start command sent during closing causes the gate to stop for 

2” and subsequent automation re-opening.

2 s

start

STEP-STEP 

FUNCTION 

ENABLED

SW 2

SW 1

INPUT OF OPENING 

PHOTOCELL 

OR 

SENSITIVE EDGE

1

2

3

ON

4

1

2

3

ON

4

1

2

3

ON

4

1

2

3

ON

4

LED SIGNALS

LED

FINE CH

FINE AP

FOTO AP

FOTO

STOP

PED

START

ON

OFF

FUNCTION

Internal photocell

External photocell

STOP button

PEDESTRIAN button

Open/Close button

Opening  photocell free 
of obstacles

Closing photocell free 
of obstacles

Stop button in normal status

Pedestrian button pressed

Open/Close button pressed

Connection between terminals 
8-10 OK

No jumper between terminals 8-10

Opening photocell obscured 
(presence of obstacle)

Closing photocell obscured 
(presence of obstacle)

Stop button pressed

Pedestrian button in normal status

Open/Close button in normal status

DL10

Programming

Indicates the various programming phases

DL8

M2 motor control

Brightness varies depending 
on the M2 motor control 
voltage

M2 Motor not powered

DL9

M1 motor control

Brightness varies depending 
on the M1 motor control 
voltage

M1 Motor not powered

Connection between terminals 
9-10 OK

No jumper between terminals 9-10

- Sensitive edge function activated: the input on terminal 6 both on 

opening and closing inverts movement by 10cm.

- Opening photocell function activated: connect the photocells to 

terminal 6; if obscured during opening, the gate stops, and resumes 
opening as soon as the photocell is free. If obscured during closing, 
the gate stops, and re-opens as soon as the photocell is free.

SIN

CE

 1

96

5

- A start command sent during opening causes the gate to stop.

- A subsequent start command closes the gate.

K

IT

/3

0

-3

9

F

 I

 E

Summary of Contents for KIT/30 F

Page 1: ...Compatibility Emissions CEI EN61000 6 3 Electromagnetic Compatibility Immunity CEI EN61000 6 Apart from the legislation mentioned above you are also reminded to comply with the following standards dur...

Page 2: ...T 38 1 KIT 30F KIT 39F COMPONENTS OF KIT 4 x 2 x 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Motors MT 30 2 KIT 30F MT 38 1 KIT 39F CR 41 Electronic control unit with built in receiver OG 62 2 channel minitra...

Page 3: ...tacts Or alternatively use a 10Athermal magnetic circuit breaker 2 Always make connections of any type with the system disconnected from the power supply i e with the main switch set to OFF symbol 0 T...

Page 4: ...of travel Fig 2 Otherwise install as necessary 3 Ensure that the distance between the gate hinge and post surface marked A in fig 2 is less than 130 mm for an opening angle of 90 less than 110 mm for...

Page 5: ...the gate is reduced due to the dimensions of the motors In this case installation of the motors on the upper section of the gate is recommended IMPORTANT Failure to observe distances B and C specifie...

Page 6: ...in fig 11 Remove the blank out disk on the right marked internally with D for the right leaf and remove the blank out disk on the left marked internally with S for the left leaf In the hole insert th...

Page 7: ...left hand side To invert the cover opening side proceed as follows WARNING This operation must be performed before fixing the enclosure to the wall Insert a slotted screwdriver in the hinge fixture sl...

Page 8: ...e screws Advice for wiring up in non specialised environments 1 Fit an omnipolar switch upstream of the system choosing one with a gap of at least 3mm between the contacts Or alternatively use a 10A t...

Page 9: ...the noise it is possible to add a bridge rectifier as per diagram BUILT IN RECEIVER ANTENNA Input for antenna connection for built in receiver 23 SHEATH 24 ANTENNA GATE OPEN INDICATOR LIGHT 24Vdc outp...

Page 10: ...ng the power supply voltage via the Power potentiometer on the SERAI CR 41 control unit In any event installation must be in full observance with current standards governing power operated gates remem...

Page 11: ...he power supply any new microswitch settings are applied on subsequent start up After making new settings on microswitches we recommend repeating the work time programming procedure see control unit p...

Page 12: ...rmal status Pedestrian button pressed Open Close button pressed Connection between terminals 8 10 OK No jumper between terminals 8 10 Opening photocell obscured presence of obstacle Closing photocell...

Page 13: ...ding of our motors That is why we recommend you check the impact force setting at the start of winter and summer WARNING If one or more parameters are altered programming must be repeated from the beg...

Page 14: ...N When the leaf reaches the closing stop let at least 5 seconds pass and then press key C WORK once Motor M1 is shut down and the control unit automatically exits the programming phase and is ready fo...

Page 15: ...e right hand button 1 OG 02 or OG 04 microswitch operated mini transmitter as pedestrian control there is no need to store the other OG 02 and OG 04 transmitters simply set the microswitches in the sa...

Page 16: ...optional addition of the SOG 2A expansion bo ard which takes the number of mini transmitters up to 794 After fitting the SOG 4A receiver all the codes stored in the built in receiver must be erased a...

Page 17: ...emperature 10 60 C Dimensions 70 x 40 x 90 mm Weight 120 g RX RX THE CONTACT POSITION REFERS TO WHEN THE RECEIVER IS ENERGIZED 40 mm POSITION DIMENSIONS INSTALLATION RX SPHERICAL ORANGE LAMP WITH BUIL...

Page 18: ...dip2 SW2 set to ON KIT 30 39F I E 10 18 110607 A4Vf r IS KIT30F IS E The remote control range is reduced Unsuitable antenna connection Check that the antenna is connected correctly to terminals 23 and...