Page 12/18
STEP-STEP
FUNCTION
DISABLED
D
U
R
IN
G
O
P
E
N
IN
G
- A start command sent during closing causes the gate to stop for
2” and subsequent automation re-opening.
- A start command sent during opening is ignored, while during the
gate open pause causes closure.
D
U
R
IN
G
C
L
O
S
U
R
E
2 s
start
start
start
start
D
U
R
IN
G
O
P
E
N
IN
G
D
U
R
IN
G
C
L
O
S
U
R
E
COMMAND SENT
DURING
GATE MOVEMENT
MICROSWITCH
SETTINGS
DESCRIPTION OF OPERATION
OPERATION
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
- A start command sent during closing causes the gate to stop for
2” and subsequent automation re-opening.
2 s
start
STEP-STEP
FUNCTION
ENABLED
SW 2
SW 1
INPUT OF OPENING
PHOTOCELL
OR
SENSITIVE EDGE
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
1
2
3
ON
4
LED SIGNALS
LED
FINE CH
FINE AP
FOTO AP
FOTO
STOP
PED
START
ON
OFF
FUNCTION
Internal photocell
External photocell
STOP button
PEDESTRIAN button
Open/Close button
Opening photocell free
of obstacles
Closing photocell free
of obstacles
Stop button in normal status
Pedestrian button pressed
Open/Close button pressed
Connection between terminals
8-10 OK
No jumper between terminals 8-10
Opening photocell obscured
(presence of obstacle)
Closing photocell obscured
(presence of obstacle)
Stop button pressed
Pedestrian button in normal status
Open/Close button in normal status
DL10
Programming
Indicates the various programming phases
DL8
M2 motor control
Brightness varies depending
on the M2 motor control
voltage
M2 Motor not powered
DL9
M1 motor control
Brightness varies depending
on the M1 motor control
voltage
M1 Motor not powered
Connection between terminals
9-10 OK
No jumper between terminals 9-10
- Sensitive edge function activated: the input on terminal 6 both on
opening and closing inverts movement by 10cm.
- Opening photocell function activated: connect the photocells to
terminal 6; if obscured during opening, the gate stops, and resumes
opening as soon as the photocell is free. If obscured during closing,
the gate stops, and re-opens as soon as the photocell is free.
SIN
CE
1
96
5
- A start command sent during opening causes the gate to stop.
- A subsequent start command closes the gate.