DA
L
19
65
Pag. 3/18
1
230V
3 x 1,5
4 x 0,5
2 x 0,5
4 x 0,5
4 x 1,5
4 x 1,5
2 x 0,5
3 x 0,5
RG58
2 X 1,5
1
2
4
5
5
3
6
MT/30/2
MT/38/1
Power supply
230 V~ ±10% 50/60 Hz
230V~ ±10% - 50/60 Hz
Max. leaf length
3,00 m
2,00 m
Max. leaf weight
300 kg
200 kg
Max. opening angle
110°
110°
Max. absorption
1,6 A
1,6 A
Power
150 W
150 W
Max. torque
180 Nm
120 Nm
Max. thrust
1200 N
1200 N
Angular speed
0,09 rad/s
0,11 rad/s
Opening time for 90°
17 s
17 s
Motor force adjusted:
via power supply voltage control
Capacitor
12,5µF
12,5µF
Motor thermal protection
150°
150°
Protection rating
IP55
IP55
Operating temperature
-20°C ÷ +60°C
-20°C ÷ +60°C
Dimensions
950 x 115 x 80 mm
750 x 115 x 80 mm
Weight
9 kg
7,5 kg
4
M/10 electric key
5
Pair of P/10 photocells
6
RZ/20 F Flashing light with antenna
SYSTEM TYPE
1
MT/30/2, MT/38/1 gearmotor
2
CR/41 electronic control unit with built-in receiver
3
OG/62 2-channel minitransmitter
Advice for wiring up in non-specialised environments.
1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or,
alternatively, use a 10A thermal magnetic circuit breaker.
2. Always make connections, of any type, with the system disconnected from the power supply, i.e. with the main switch
set to OFF (symbol “0”). The control unit, in particular, must never be connected to the power supply either during the
wiring up, or when fitting any expansion boards.
3. The following cables must be used for installation of the system:
2
2
- for the control unit, motor and electric lock power supplies: 1.5mm section for lengths of up to 19m, 2.5mm section
for lengths of up to 31m,
2
2
- for the flashing light: 0.75mm section for lengths of up to 3m, 1.5mm section for lengths of up to 19m,
- for the low voltage and current lines, (e.g. for the photocells, control buttons, electromechanical key, sensitive
2
2
edges and other safety devices: 0.5mm section for lengths of up to 50m, 0.75mm section for lengths of up to 100m.
4. Wire up the earth connection in compliance with legal provisions.
GEARMOTOR TECHNICAL SPECIFICATIONS
The technical data refer to an ambient temperature of 25°C with intermediate force setting.
Lower operating temperatures or higher stress levels could require increased force settings. The opposite applies
for higher temperatures or lower stress levels.
K
IT
/3
0
-3
9
F
I
E