CR/41 CONTROL UNIT TECHNICAL SPECIFICATIONS

Power supply:

230Vac ±10% 50/60Hz

Motor power supply:

2 single-phase motor, 230Vac, 200W+200W

Power supply for accessories:

24Vac, 500mA

Flashing light power supply:

230Vac, max 50W

Courtesy light power supply:

230Vac, max 100W

Electric lock power supply:

12Vac 15VA

Motor work time setting:

from 0 to 120s

Pause time setting:

from 4 to 120s

Offset level on opening and closing:

from 0 to 15s

Operating temperature:

-20°C ÷ +70°C

Protection rating:

IP54

Dimensions (H x L x D) and weight:

270x212x118mm, 1.7Kg 

Page 16/18

EXPANDING THE NUMBER OF MINI TRANSMITTERS

If the 32 mini transmitters storable in the built-in receiver are not sufficient, they can be increased by fitting the SOG/4A 
receiver (which takes the number of mini transmitters up to 40), with the optional addition of the SOG/2A expansion bo-
ard (which takes the number of mini transmitters up to 794). 

After fitting the SOG/4A receiver, all the codes stored in the built-in receiver must be erased and all the mini tran-
smitters on the new SOG/4A receiver reprogrammed (see specific instructions). The antenna must be moved 
from the terminal on the control unit to the terminal on the SOG/4A.

SIN

CE

 1

96

5

K

IT

/3

0

-3

9

F

 I

 E

nd

2  CHANNEL 

OUTPUT: 

AUXILIARY 

CONTROL

ANTENNA

NC

C

NO

Channel 2 output (relay 
contact)

Max. applicable voltage = 

24Vac/dc

Max. applicable current = 

1A

ELECTRIC LOCKS

LIGHTS

OTHER AUTOMATIONS

OTHER

FIT THE 
SOG/4A 
RECEIVER

st

1  CHANNEL 

OUTPUT: 

CONTROL UNIT 

START CONTROL

PEDESTRIAN CONTROL 

ON CR/41 -TERMINALS 1-2-

DISCONNECT THE POWER 
SUPPLY BEFORE WORKING 
ON THE WIRING

NO

NC

F1F1

F2

F2

ON

SW1

SW2

3 4 5 6 7 8

SOG/4

POWER

+

-

ON

PED

START STOP FOTO FOTO AP FINE CH FINE AP

DL9

DL8

DL10

1 2

9 10

11121314 1516171819 20

21

22

27

2526

2324

SET

BREAK

WORK

A

B

C

Com

+24

spia

RX

2829

Summary of Contents for KIT/30 F

Page 1: ...Compatibility Emissions CEI EN61000 6 3 Electromagnetic Compatibility Immunity CEI EN61000 6 Apart from the legislation mentioned above you are also reminded to comply with the following standards dur...

Page 2: ...T 38 1 KIT 30F KIT 39F COMPONENTS OF KIT 4 x 2 x 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Motors MT 30 2 KIT 30F MT 38 1 KIT 39F CR 41 Electronic control unit with built in receiver OG 62 2 channel minitra...

Page 3: ...tacts Or alternatively use a 10Athermal magnetic circuit breaker 2 Always make connections of any type with the system disconnected from the power supply i e with the main switch set to OFF symbol 0 T...

Page 4: ...of travel Fig 2 Otherwise install as necessary 3 Ensure that the distance between the gate hinge and post surface marked A in fig 2 is less than 130 mm for an opening angle of 90 less than 110 mm for...

Page 5: ...the gate is reduced due to the dimensions of the motors In this case installation of the motors on the upper section of the gate is recommended IMPORTANT Failure to observe distances B and C specifie...

Page 6: ...in fig 11 Remove the blank out disk on the right marked internally with D for the right leaf and remove the blank out disk on the left marked internally with S for the left leaf In the hole insert th...

Page 7: ...left hand side To invert the cover opening side proceed as follows WARNING This operation must be performed before fixing the enclosure to the wall Insert a slotted screwdriver in the hinge fixture sl...

Page 8: ...e screws Advice for wiring up in non specialised environments 1 Fit an omnipolar switch upstream of the system choosing one with a gap of at least 3mm between the contacts Or alternatively use a 10A t...

Page 9: ...the noise it is possible to add a bridge rectifier as per diagram BUILT IN RECEIVER ANTENNA Input for antenna connection for built in receiver 23 SHEATH 24 ANTENNA GATE OPEN INDICATOR LIGHT 24Vdc outp...

Page 10: ...ng the power supply voltage via the Power potentiometer on the SERAI CR 41 control unit In any event installation must be in full observance with current standards governing power operated gates remem...

Page 11: ...he power supply any new microswitch settings are applied on subsequent start up After making new settings on microswitches we recommend repeating the work time programming procedure see control unit p...

Page 12: ...rmal status Pedestrian button pressed Open Close button pressed Connection between terminals 8 10 OK No jumper between terminals 8 10 Opening photocell obscured presence of obstacle Closing photocell...

Page 13: ...ding of our motors That is why we recommend you check the impact force setting at the start of winter and summer WARNING If one or more parameters are altered programming must be repeated from the beg...

Page 14: ...N When the leaf reaches the closing stop let at least 5 seconds pass and then press key C WORK once Motor M1 is shut down and the control unit automatically exits the programming phase and is ready fo...

Page 15: ...e right hand button 1 OG 02 or OG 04 microswitch operated mini transmitter as pedestrian control there is no need to store the other OG 02 and OG 04 transmitters simply set the microswitches in the sa...

Page 16: ...optional addition of the SOG 2A expansion bo ard which takes the number of mini transmitters up to 794 After fitting the SOG 4A receiver all the codes stored in the built in receiver must be erased a...

Page 17: ...emperature 10 60 C Dimensions 70 x 40 x 90 mm Weight 120 g RX RX THE CONTACT POSITION REFERS TO WHEN THE RECEIVER IS ENERGIZED 40 mm POSITION DIMENSIONS INSTALLATION RX SPHERICAL ORANGE LAMP WITH BUIL...

Page 18: ...dip2 SW2 set to ON KIT 30 39F I E 10 18 110607 A4Vf r IS KIT30F IS E The remote control range is reduced Unsuitable antenna connection Check that the antenna is connected correctly to terminals 23 and...

Reviews: