background image

TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION

The gearmotor 
is not working

No power supply 
to motors

Check voltage presence on motor power supply input
terminals 

Ensure that the power cable is not detached and is intact
(cable replacement must be carried out by an authorised 
technician)

Check the control unit fuses

No power supply 
to control unit

Check the mains fuse and presence of mains power voltage

Motor thermal protection
activated

Leave the motor stationary for at least 10-15 minutes and then 
check operation again

The gate 
does not 
complete 
its travel

Gate blocked

Ensure that there are no obstacles by moving the gate manually. 
Remove any obstacles if present.

Unsuitable bracket 
position

The brackets are not positioned according to values A, B, 
and C

The gate is slow 
and start-up 
is problematic 

Capacitor failure

Measure the capacitor capacity and replace 
if necessary

Incorrect motor force 
setting

Repeat programming, increasing the motor force by means 
of the potentiometer “Power”

Incorrect work 
times

Repeat the work time programming

Start-up torque 
deactivated

Check the relative microswitch on the board

Incorrect deceleration 
settings

Ensure that the set deceleration speed is sufficient to move 
the gate; if necessary disable deceleration 
(dip2 SW2 set to ON)

K

IT

/3

0

-3

9

F

 I

 E

  

1

0

  

1

8

  

1

1

0

6

0

7

 -

 A

4

V

f/

IS

 K

IT

3

0

F

-I

S

-E

The remote 
control range 
is reduced

Unsuitable antenna 
connection

Check that the antenna is connected correctly to 
terminals 23 and 24

External antenna
required

To permit maximum reception distance, replace the 
internal antenna on the flashing light with an external 
one (SERAI OG/50 -SR 25.50)

SOG/4A receiver 
in use

Replace the built-in receiver with the SOG/4A 
card

E L E T T R O N I C A        P A D O V A 

I

S

IN

C

E

 1

9

6

5

M A D E   I N   I T A L Y
VIA ENRICO FERMI, 22
35020 LEGNARO - PADOVA
I   T   A   L   I   A

PHONE           +39 049 79 08 58
FAX               +39 049 88 30 529

E-MAIL   [email protected]
WEB        www.serai.com

TERMS OF GUARANTEE

The company reserves the right to make modifications to the equipment without prior notice thereof. SERAI products are covered by a standard guarantee with a term of 24 months. 
Coverage starts on the date on which the tax document constituting proof of purchase is issued and guarantee services shall be provided on the company's premises at Legnaro - PD - 
or at the Authorised Service Centres. Carriage costs shall be borne by the Customer. 

CE CONFORMITY DECLARATION

SERAI spa declares that the product KIT/30F, KIT/39F has been desifned and manufactured according to the above mentioned directives and standards

WEEE DIRECTIVE 2002/96/EC

This appliance was manufactured after 13/08/2005. To protect the environment: when the equipment is no longer needed, take it to a special WEEE (Waste Electric and 
Electronic Equipment) collection centre. Do not dispose of it with normal household waste.

Summary of Contents for KIT/30 F

Page 1: ...Compatibility Emissions CEI EN61000 6 3 Electromagnetic Compatibility Immunity CEI EN61000 6 Apart from the legislation mentioned above you are also reminded to comply with the following standards dur...

Page 2: ...T 38 1 KIT 30F KIT 39F COMPONENTS OF KIT 4 x 2 x 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Motors MT 30 2 KIT 30F MT 38 1 KIT 39F CR 41 Electronic control unit with built in receiver OG 62 2 channel minitra...

Page 3: ...tacts Or alternatively use a 10Athermal magnetic circuit breaker 2 Always make connections of any type with the system disconnected from the power supply i e with the main switch set to OFF symbol 0 T...

Page 4: ...of travel Fig 2 Otherwise install as necessary 3 Ensure that the distance between the gate hinge and post surface marked A in fig 2 is less than 130 mm for an opening angle of 90 less than 110 mm for...

Page 5: ...the gate is reduced due to the dimensions of the motors In this case installation of the motors on the upper section of the gate is recommended IMPORTANT Failure to observe distances B and C specifie...

Page 6: ...in fig 11 Remove the blank out disk on the right marked internally with D for the right leaf and remove the blank out disk on the left marked internally with S for the left leaf In the hole insert th...

Page 7: ...left hand side To invert the cover opening side proceed as follows WARNING This operation must be performed before fixing the enclosure to the wall Insert a slotted screwdriver in the hinge fixture sl...

Page 8: ...e screws Advice for wiring up in non specialised environments 1 Fit an omnipolar switch upstream of the system choosing one with a gap of at least 3mm between the contacts Or alternatively use a 10A t...

Page 9: ...the noise it is possible to add a bridge rectifier as per diagram BUILT IN RECEIVER ANTENNA Input for antenna connection for built in receiver 23 SHEATH 24 ANTENNA GATE OPEN INDICATOR LIGHT 24Vdc outp...

Page 10: ...ng the power supply voltage via the Power potentiometer on the SERAI CR 41 control unit In any event installation must be in full observance with current standards governing power operated gates remem...

Page 11: ...he power supply any new microswitch settings are applied on subsequent start up After making new settings on microswitches we recommend repeating the work time programming procedure see control unit p...

Page 12: ...rmal status Pedestrian button pressed Open Close button pressed Connection between terminals 8 10 OK No jumper between terminals 8 10 Opening photocell obscured presence of obstacle Closing photocell...

Page 13: ...ding of our motors That is why we recommend you check the impact force setting at the start of winter and summer WARNING If one or more parameters are altered programming must be repeated from the beg...

Page 14: ...N When the leaf reaches the closing stop let at least 5 seconds pass and then press key C WORK once Motor M1 is shut down and the control unit automatically exits the programming phase and is ready fo...

Page 15: ...e right hand button 1 OG 02 or OG 04 microswitch operated mini transmitter as pedestrian control there is no need to store the other OG 02 and OG 04 transmitters simply set the microswitches in the sa...

Page 16: ...optional addition of the SOG 2A expansion bo ard which takes the number of mini transmitters up to 794 After fitting the SOG 4A receiver all the codes stored in the built in receiver must be erased a...

Page 17: ...emperature 10 60 C Dimensions 70 x 40 x 90 mm Weight 120 g RX RX THE CONTACT POSITION REFERS TO WHEN THE RECEIVER IS ENERGIZED 40 mm POSITION DIMENSIONS INSTALLATION RX SPHERICAL ORANGE LAMP WITH BUIL...

Page 18: ...dip2 SW2 set to ON KIT 30 39F I E 10 18 110607 A4Vf r IS KIT30F IS E The remote control range is reduced Unsuitable antenna connection Check that the antenna is connected correctly to terminals 23 and...

Reviews: