background image

Page 9/18

SIN

CE

 1

96

5

K

IT

/3

0

-3

9

F

 I

 E

O

P

E

N

C

L

O

S

E

C

O

M

M

O

N

FLASHING LIGHT 

 230V~

COURTESY LIGHT 

 230V~

O

P

E

N

C

L

O

S

E

C

O

M

M

O

N

PED

CLOSING

PHOTOCELL

RECEIVER

TRANSMITTER

RECEIVER

TRANSMITTER

PEDESTRIAN

ELECTRIC LOCK

TYPE SERAI M/83/1

WIRING DIAGRAM 

OP. DELAY

DISCONNECT THE POWER 
SUPPLY BEFORE WORKING 
ON THE WIRING

TERMINALS CONNECTIONS

DESCRIPTION

POWER SUPPLY

Card power supply input 230V~ ±10% 50/60 Hz

FLASHING LIGHT

Flashing light power output (230Vac-

max 50W

) to use with flashing light without 

internal electronics -type SERAI 

RZ/20 F

-.

COURTESY LIGHT

Courtesy light output (230Vac-

max 100W

): active for 90 seconds after STOP 

MOTOR M1

M1 motor power output (14=Common, 15=Opening, 16=Closing) for single leaf or 
pedestrian access (connected to electric lock)

PHOTOCELL

POWER SUPPLY

24Vac power output (

max 500mA

) for accessories such as photocells

OPENING

PHOTOCELL / 

SENSITIVE EDGE

DO NOT USE

Short circuit on common with jumpers.

CLOSING

PHOTOCELL

PEDESTRIAN

CONTROL

Pedestrian control input (NO contact). With DIP1 SW1 set to OFF only the leaf 
connected to M1 opens. With DIP1 SW1 set to ON the single leaf opens for 7s.

STOP BUTTON

Stop command input (NC contact); when pressed, blocks motor operation; 
if pressed during gate open pause time cancels automatic 
re-closure.

START

CONTROL

Start command input (NO contact) controls opening and closing in step-step
mode.

Input for photocell active during closure only (NC contact). if obscured 
during closure, the gate stops and then opens again.

INPUT

COMMON

Input common terminals.

MOTOR M2

M2 motor power output (17=Common, 18=Opening, 19=Closing) for motor 
delayed on opening (2-leaf gates)

ELECTRIC LOCK

COMMAND

12Vac 15VA max output for the direct command electric lock SERAI M/83/1. To 
reduce the noise it is possible to add a bridge rectifier as per diagram *

BUILT-IN

RECEIVER

ANTENNA 

Input for antenna connection for built-in receiver. (23=

SHEATH

24=

ANTENNA

)

GATE OPEN

INDICATOR

LIGHT

24Vdc output (28 +, 29 -) 

max 50mA

 for gate open indicator connection. 

WARNING: to connect indicator lights with consumption of more 
than 50mA use a suitable supplementary external relay

21 - 22

11 - 12

12 - 13

14 - 15 - 16

26 - 27

6

    8 - 9

5

2

4

3

 1 - 7 - 10

17 - 18 - 19

25 - 26

23 - 24

28 - 29

20

DO NOT USE

S

U

P

P

L

E

M

E

N

T

A

R

Y

R

E

L

A

Y

2

4

V

d

c

 -

 m

a

x

 5

0

m

A

29

28

INDICATOR

LIGHT

INDICATOR LIGHT

POWER SUPPLY

OPENING PHOTOCELL

(or SENSITIVE EDGE)

With DIP4 SW2 set to OFF: input for photocell active during both closure and 
opening (NC contact). If obscured during opening, the gate stops, and resumes 
opening as soon as the photocell is free. If obscured during closing, the gate 
stops, and re-opens as soon as the photocell is free. 
With DIP4 SW2 ON: Sensitive edge input (NC contact); inverts movement by 10 cm. 

FUSES:

F1 = T1,6A  250V~ 
-slow acting-
-ACCESSORIES 24V-

F2 =  5A   250V~ 
-istant-
-POWER SUPPLY 230V-

F1F1

F2

F2

ON

SW1

SW2

3 4 5 6 7 8

SOG/4

POWER

+

-

ON

PED

START STOP FOTO FOTO AP FINE CH FINE AP

DL9

DL8

DL10

1 2

9 10

11121314 1516171819 20

21

22

27

2526

2324

230Vac ±10%

50/60Hz

F

N

M2

M1

N

C

N

C

NC

NC

NA

NC

NA

START

STOP

24 Vac

SET

BREAK

WORK

A

B

C

Com

+24

spia

12Vac

RX

2829

+

-

230Vac

BRIDGE RECTIFIER

SUPPLEMENTARY

RELAY

12Vac

TRANSFORMER

230/12Vac

-SERAI TR/01-

F
N

ELECTRIC LOCK NOISE REDUCTION

To reduce the noise of the electric lock it is possible to 
add an ordinary bridge rectifier 50V 4A connected as per 
below indicated diagram

230Vac

12Vdc

12Vac

12Vac

*

~

ELECTRIC LOCK

TYPE SERAI M/83/1

SW1= 

Microswitches for control 
unit setting - see 
microswitch settings -

A= 

Button to enter programming 

mode (SET)

B= 

Button for time programming 

(BREAK)

C= 

Button for time programming 

(WORK)

POWER= 

Trimmer for motor 

                 force adjustment

SW2= 

Microswitches for control 
unit setting - see 
microswitch settings -

Summary of Contents for KIT/30 F

Page 1: ...Compatibility Emissions CEI EN61000 6 3 Electromagnetic Compatibility Immunity CEI EN61000 6 Apart from the legislation mentioned above you are also reminded to comply with the following standards dur...

Page 2: ...T 38 1 KIT 30F KIT 39F COMPONENTS OF KIT 4 x 2 x 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Motors MT 30 2 KIT 30F MT 38 1 KIT 39F CR 41 Electronic control unit with built in receiver OG 62 2 channel minitra...

Page 3: ...tacts Or alternatively use a 10Athermal magnetic circuit breaker 2 Always make connections of any type with the system disconnected from the power supply i e with the main switch set to OFF symbol 0 T...

Page 4: ...of travel Fig 2 Otherwise install as necessary 3 Ensure that the distance between the gate hinge and post surface marked A in fig 2 is less than 130 mm for an opening angle of 90 less than 110 mm for...

Page 5: ...the gate is reduced due to the dimensions of the motors In this case installation of the motors on the upper section of the gate is recommended IMPORTANT Failure to observe distances B and C specifie...

Page 6: ...in fig 11 Remove the blank out disk on the right marked internally with D for the right leaf and remove the blank out disk on the left marked internally with S for the left leaf In the hole insert th...

Page 7: ...left hand side To invert the cover opening side proceed as follows WARNING This operation must be performed before fixing the enclosure to the wall Insert a slotted screwdriver in the hinge fixture sl...

Page 8: ...e screws Advice for wiring up in non specialised environments 1 Fit an omnipolar switch upstream of the system choosing one with a gap of at least 3mm between the contacts Or alternatively use a 10A t...

Page 9: ...the noise it is possible to add a bridge rectifier as per diagram BUILT IN RECEIVER ANTENNA Input for antenna connection for built in receiver 23 SHEATH 24 ANTENNA GATE OPEN INDICATOR LIGHT 24Vdc outp...

Page 10: ...ng the power supply voltage via the Power potentiometer on the SERAI CR 41 control unit In any event installation must be in full observance with current standards governing power operated gates remem...

Page 11: ...he power supply any new microswitch settings are applied on subsequent start up After making new settings on microswitches we recommend repeating the work time programming procedure see control unit p...

Page 12: ...rmal status Pedestrian button pressed Open Close button pressed Connection between terminals 8 10 OK No jumper between terminals 8 10 Opening photocell obscured presence of obstacle Closing photocell...

Page 13: ...ding of our motors That is why we recommend you check the impact force setting at the start of winter and summer WARNING If one or more parameters are altered programming must be repeated from the beg...

Page 14: ...N When the leaf reaches the closing stop let at least 5 seconds pass and then press key C WORK once Motor M1 is shut down and the control unit automatically exits the programming phase and is ready fo...

Page 15: ...e right hand button 1 OG 02 or OG 04 microswitch operated mini transmitter as pedestrian control there is no need to store the other OG 02 and OG 04 transmitters simply set the microswitches in the sa...

Page 16: ...optional addition of the SOG 2A expansion bo ard which takes the number of mini transmitters up to 794 After fitting the SOG 4A receiver all the codes stored in the built in receiver must be erased a...

Page 17: ...emperature 10 60 C Dimensions 70 x 40 x 90 mm Weight 120 g RX RX THE CONTACT POSITION REFERS TO WHEN THE RECEIVER IS ENERGIZED 40 mm POSITION DIMENSIONS INSTALLATION RX SPHERICAL ORANGE LAMP WITH BUIL...

Page 18: ...dip2 SW2 set to ON KIT 30 39F I E 10 18 110607 A4Vf r IS KIT30F IS E The remote control range is reduced Unsuitable antenna connection Check that the antenna is connected correctly to terminals 23 and...

Reviews: