background image

Freevia 280

Freevia 300

Operating and installation guide

Instrukcja montażu i obsługi

5057966C

Summary of Contents for Freevia 280

Page 1: ...Freevia 280 Freevia 300 Operating and installation guide Instrukcja montażu i obsługi 5057966C ...

Page 2: ...FreeVia 280 FreeVia 300 8 14 17 15 16 6 11 9 9 8 12 20 10 3 7 21 22 18 1 2 5 4 13 19 ...

Page 3: ...ng 9 3 Electrical connections 12 4 Quick commissioning 14 5 Fitting the cover 15 operation 16 Operation in sequential mode 16 Operation in automatic mode 17 Obstacle detection operation 17 Area lighting operation 17 Operation of the 3 button control points or remote controls 18 Unlocking locking the motor 18 Advanced parameter setting 19 Selecting the buttons of your 2 or 4 button remote control 1...

Page 4: ...tructions Before installing your motor carefully read all the instructions in this guide All the instructions given must be followed closely and this guide must be stored in a safe place throughout the service life of your product Failure to follow these installation instructions may result in serious injury or damage to the equipment Somfy shall not be held liable in this event This device is not...

Page 5: ...ion and Switzerland example interphone key lock code keypad Product description This motor is designed for sliding doors on individual residential properties Composition of the kit No Description Quantity 1 Cover 1 2 Aerial 1 3 Electronic unit 1 4 Motor 1 5 Cover screw 1 6 O ring 9 x 2 1 7 Rack 33 cm 12 8 Galvanised screw M10 8 9 Galvanised medium plain washer 10 5 x 22 x 2 8 10 Cable grommet 1 11...

Page 6: ...mm Ambient light detector The motor s electronic unit is fitted with an ambient light detector which detects whether or not the cover is fitted This means that settings mode is only available when the cover is removed If the cover is fitted the motor is in standby mode 84 72 232 48 109 218 214 109 180 25 Light sensor ...

Page 7: ...andard EN 12 453 Operating temperature 20 C to 60 C Thermal protection Yes Protection rating IP 44 Integrated radio receiver Yes Remote controls Radio frequency Range in field of use Storage quantity 433 42 MHz 50 m 16 Possible connections Output for orange light Area lighting output contact supplied Accessories supply output Backup battery input Photoelectric cell input Dry contact control input ...

Page 8: ...cking points that may prevent it from sliding correctly Types of gates which can be motorised Your motor can be adapted to all types of sliding door PVC wood metal etc For a barred gate with bars spaced more than 50 mm apart it is essential to install a mesh 40 x 40 mm type along the entire length of the gate This will prevent any risk of trapping see mark C opposite Fitting end stops to the gate ...

Page 9: ...ic mode and for opening in public areas Cell wiring see page 23 Ensure that there is a sheathed connection between the two pillars for the cell wiring Drill holes in the two ends of the gate frame to feed through the sheaths The cells must be connected to the motor electronics using a 2 x 0 75 mm cable The feed wires should arrive under the cells Cell location see page 22 Orange light optional It ...

Page 10: ...of the ground Allow for the supply cable to be fed through according to the electrical standards in force in the country of use 1 Preparing the base Steps Positioning the motor Fitting the end stops Base Positioning the motor Horizontal position Ensure that the motor is always positioned in the field of the gate when opening and closing Vertical position Ensure that the motor is raised off the gro...

Page 11: ...right height in relation to the ground fix it in place using the washers 9 and tighten the 4 nuts 8 5 Position the pre drilled grommet 10 in the opening through which the supply cable should be fed Steps Fitting the lag screws Mounting the motor Fitting the rack Mechanical adjustment Fitting the lag screws 1 Position the installation template 18 on the ground and drill 4 holes using a drill bit Ø ...

Page 12: ...n the notches provided on the motor With the other hand slide the gate to trace the height of the rack mounting 3 Fixaninitialrackcomponent 7 by positioning the top of the rack on the line drawn by the pencil Fix the other rack components in the same way Use HSHC head screws ø 6 to suit the gate material metal wood Up to 5 m of rack can be installed set of 3 x 33 cm rack components ref 2400962 ...

Page 13: ... its travel the pinion is correctly driven along the entire length of travel of the gate the clearance between the rack and pinion does not vary significantly over the gate s travel If these conditions are not met 1 Adjust the height and level of the motor using the 4 nuts 8 under the motor 2 Adjust the rack if necessary and tighten the motor nuts 3 Close the gate 4 Lock the motor ...

Page 14: ...s connected to the mains The motor must always be connected between terminals 9 and 10 green label M1 on the motor s electronic unit The motor 4 and the electronic unit 3 are prewired for installing the motor on the left hand side To change the direction of the motor invert the wires connected to terminals 9 and 10 Blue Black Brown Green 9 10 M1 Blue Black Brown Green 9 10 M1 Motor on left hand si...

Page 15: ...een terminals 15 and 16 of the electronic unit red 230 V label Check that the wires are correctly secured in place by pulling them gently upwards Terminal Blue wire N 15 Red brown black wire L 16 Green and yellow wire The colour coding of the wires must be followed Connection to a solar power supply See page 29 Safety device connection Cells sold as an option in the Freevia 280 pack See pages 22 a...

Page 16: ...mming the gate travel The motor s electronics automatically store The motor torque required to control the gate in normal operation Once this is stored this enables any abnormal motor effort to be detected The travel distances required to fully open and close the gate with the positions of the end stops During programming you should remain at a normal distance from the gate and follow the steps be...

Page 17: ...ce the cover on the motor bracket base 2 Fit the gasket 6 to ensure that the motor is sealed and fit the cover screw 5 3 Screw on the cover using the key provided 7 YOUR MOTOR IS READY TO OPERATE By default it operates in sequential mode opening automatically 2 1 ...

Page 18: ...utton 1 Open the gate completely by pressing button 1 Partial opening of the gate approx 1 m by pressing the activated button Complete opening Pedestrian opening Close the gate by pressing the activated button Close the gate by pressing button 1 again Stop the gate when moving by pressing button 1 again Pedestrian opening is achieved by pressing a button on the remote control that requires prior a...

Page 19: ... automatic mode the gate will close automatically after 30 seconds In case an obstacle is detected on closing the gate stops and opens fully Close the gate by pressing button 1 Obstacle detection operation If an obstacle is detected on opening the gate stops and moves backwards slightly on closing the gate stops and opens fully Area lighting operation Area lighting comes on each time the motor is ...

Page 20: ...t If the motor is placed in the unlocked position the gate can be moved manually in the event of an electrical power failure The gate is thus totally free to move Move it carefully Unlock the motor by pulling the handle towards you Lock the motor by pushing the handle towards the gate Operation of the 3 button remote controls or control points The gate is opened by pressing the up button The gate ...

Page 21: ... remote control has been stored 0 5s If you have stored 16 remote controls and you store a 17th remote control the first remote control stored will be deleted and so on 0 5s Note The motor parameter setting cannot be carried out when the gate is moving Changes to the parameters will be taken into account after the first time the gate is opened Selection of the buttons of your 2 or 4 button remote ...

Page 22: ... deactivate automatic closing mode and return to sequential mode repeat step 1 above and briefly press button 2 on the remote control theAUTO CLOSE indicator will go out and then flash Press button 1 on the remote control twice 2 3 1 x2 1 Place a memorised 2 or 4 button remote control on the target Press button 1 on the remote control until the AUTO CLOSING indicator flashes 2 Press button 2 on th...

Page 23: ...21 EN Accessories Cable cross section by type of accessory ...

Page 24: ...he gate when an obstacle is detected cells blocked Note If the gate is closed and the cells are blocked the gate will not open A set of cells comprises one transmitter cell TX one receiver cell RX 2 8 m 25 cm max 20 cm Cell location Cell installation and wiring 1 2 Ø4 5 6 mm 12 mm 6 Ø4 3 4 ...

Page 25: ... not light up adjust the alignment of the cell RX using a shim Check again If the receiver cell indicator lights up continuously correct alignment refit the receiver cell RX cover RX TX 1 2 1 2 3 5 10 1 2 TX 7 1 2 3 5 RX 9 8 11 11a 11b To check the cell alignment the transmitter cell cover must be fitted but not the receiver cell cover ...

Page 26: ...top and reverse its movement If the gate is closed and the cells are blocked the gate will not open Safety instructions The correct operation of the cells must be checked every 6 months To do this when the gate is closing block one cell with your hand The gate should stop and open again 1 Place a memorised 2 or 4 button remote control on the target Press button 1 on the remote control until the AU...

Page 27: ...ght warns that the motor is about to operate It starts to flash 2 seconds before the gate begins to move Installing the orange light There are two ways of installing the orange light see fig 4a and 4b Ø3 4b 1 2 3 Ø3 4a 5 10 9 8 11 6 6 mm 12 mm 7 ...

Page 28: ...remote controls and the radio control points Note The STATUS indicator flashes 1 pulse when the motor is battery operated Battery technical data Operation time 10 continuous cycles or 24 hours on gate in perfect condition Optimum charge time before using the battery 48 hours charge Battery service life 3 years To optimise the service life of the battery cut the electrical power to the gate 3 times...

Page 29: ...he battery to the terminal provided for this purpose grey BATT label on the electronic unit Connect the interphone to terminals 3 and 4 yellow BUS label on the electronic unit Note If you want to connect a different interphone to the one above ensure that it has an output contact which is not connected to the power supply This accessory is not compatible with solar power Interphone ref 2400552 ...

Page 30: ...C1 of the digicode to terminals 3 and 4 yellow BUS label on the electronic unit V and V of the digicode to terminals 5 and 6 black 24V label on the electronic unit The aerial wire can be replaced with an offset aerial with a greater range This is placed on top of the pillar and must be clearly accessible Connect the aerial to terminals 1 and 2 blue ANT label on the electronic unit the wire core to...

Page 31: ...orange light remain active Note When the motor is operated using solar power the wired controls are deactivated and the gate can only be controlled using the remote controls and the radio control points 1 2 3 Never connect your motor to a 230 V feed when it is connected to a solar feed you may damage the motor s electronic unit In order to limit the energy consumption of your gate motor we recomme...

Page 32: ...the supply cable Outdoor lighting very low motor on standby Increase the light around the electronic unit using a torch for example if you want to make adjustments The STATUS indicator of the electronic unit is flashing 1 pulse Operation using the backup battery Check the power supply 2 pulses Motor waiting for gate travel to be programmed Begin the programming of the gate travel see page 14 3 pul...

Page 33: ... the motor wiring see page 12 The automatic closing mode does not activate the AUTO CLOSE indicator stays off Photoelectric cells not installed Install some cells see pages 22 and 23 Assistance If the fault remains or for any other problem or enquiry relating to your motors contact one of our Somfy Hotline advisors on 0113 391 30 30 Replacing the remote control battery The service life of the batt...

Page 34: ... indicator flashes 3 Press button 2 on the remote control until the MEMORY RESET indicator comes on Release button 2 The STATUS indicator flashes Clear the settings The cleared settings are the gate travel and automatic closing of the gate When to clear the settings After programming the gate s travel if you are modifying the motors wiring In case of spurious obstacle detection because of normal w...

Page 35: ...the remote control once The MEMORY RESET indicator flashes 3 Press button 2 on the remote control until all the indicators come on Release button 2 The STATUS indicator flashes 3 2 1 Clear the memorised settings and remote controls The cleared settings are the gate travel and automatic closing of the gate and all the memorised remote controls or radio control points ...

Page 36: ......

Page 37: ...éavis Photos non contractuelles Somfy SAS in a constant concern of evolution and improvement may modify the product without prior notice Non contractual pictures Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 01 2011 SOMFY UK Hotline 0113 391 30 30 SOMFY SP Z O O 0801 377 199 www somfy pl Somfy ...

Reviews: