background image

WARNING

CAUTION

NOTE:  DO NOT connect the Battery Back-Up Connection Cable to the 

garage door opener until you have completed Steps 1 & 2.

NOTE: DO NOT REVERSE CONNECTIONS—this WILL 

damage the Battery Back-Up Unit.

1

REQUIREMENTS

This unit is designed to work with specific garage door openers on  properly 

balanced doors with maximum height of 8 ft. and maximum weight of 500 lb.

The unit will provide operation of the door for 24 hours after a power loss.  
Your garage door opener MUST have the matching Connection Cable 

connector in the powerhead. 
Do not tamper with or rewire Connection Cable. 
Unit may be wall mounted provided mounting location is within 24 inches 

of the powerhead. 
The unit must be inserted into the mounting bracket as far as it will go, so 

that the bracket locks onto the ridges (Figure at Top Right) on top of the 

Battery Back-Up unit. This prevents the unit from moving.   
The unit must be mounted so that the Status LEDs are visible from the floor, 

and it is locked into the mounting bracket. 

This unit to be used ONLY with Genie® Operator Models  

Disconnect power before performing the following tasks.  

Do NOT drill holes in the Battery Back-Up case. 

RIDGES

4 SCREWS

COVER

MOUNTING

BRACKET

LAG SCREWS

RAFTER

OR

TRUSS

                                                  To Reduce the Risk of Fire 

                                                  or Injury to Persons 

                                              To Prevent possible Serious 

                                              Injury or Death by Electrocution 

 

A. Use only the following type and size battery 12V, 8Ah 

(Genie® P/N 37342R).

B. Do not install Battery Back-up unit on an improperly balanced 

door. An unbalanced door could cause severe injury or damage to 

this unit. Repairs and adjustments to the door must be made by 

trained service persons using proper tools and instructions.

C. Do not dispose of the battery in fire. The cells may explode.  

Check with local codes for possible disposal instructions. 

  

D. Do not open or mutilate the battery. Released electrolyte is

corrosive and candamage eyes or skin. TOXIC if swallowed.  

E. Exercise care in handling the battery to prevent shorting battery

with conducting materials such as rings, bracelets & keys.  

F. Change the battery provided with or identified for use with 

this product only in accordance with the instructions and 

limitations specified in this instruction.   

G. Observe proper polarity orientation between the battery and 

changing circuit. 

H . Do not set limits while in Battery Back-up Mode. AC power 

MUST be connected to the opener, while setting limits, for 

proper operation. 

Battery Back-Up 

for Residential Garage Door Openers

INSTALLATION INSTRUCTIONS

 

37260500131   01-2013 

              www.geniecompany.com 

INSTALLATION

 

  Step 2.    Mount

  Step 1.    Wire Battery

A.

A. Remove Cover (4 screws).

— Remove foam shipping block and throw away.

C. Replace Cover.

B. Connect RED (+) wire to RED terminal, 

BLACK (–) wire to BLACK terminal.

Method 1 - Ceiling Mount

Locate and attach mounting plate to ceiling rafter or 

truss using two 5/16" x 1-3/4" lag screws (provided).
— Drill 3/16"

 

pilot holes for lag screws.

Rafter or Truss

(2) 5/16" x 1-3/4" Lag

Mounting 

Bracket

Rafter or Truss

Drywall

(2) 5/16" x 1-3/4" Lag

Mounting 

Bracket

continued on back

          

          

          

          

          

TO P

REV

ENT

 POS

SIBL

          

          

          

          

          

SER

IOU

S IN

JUR

Y or

 DEA

TH 

from

 elec

troc

utio

n AN

D RE

DUC

E RIS

K of

 FIRE

  

— D

iscon

nect

 ALL

 elec

tric p

owe

r sou

rces 

and 

batt

ery 

       po

wer 

BEFO

RE p

erfo

rmin

g AN

Y ser

vice 

or m

ainte

nanc

e.

  

  

 

Insta

ll on

ly in 

DRY

 loca

tions

 - NO

T INT

END

ED F

OR O

UTD

OOR

 USE

.

For u

se O

NLY 

with

 Gen

ie® m

odel

 Seri

es 30

XX o

r 40X

Resid

entia

l Gar

age 

Doo

r Op

ener

s.

Use o

nly G

enie 

P/N 

3734

3R

 for re

place

men

t bat

tery.

The

 Ge

nie 

Mo

del

 OB

B-B

X

CAU

TIO

N

           

           

           

           

           

         P

ARA

 EVIT

AR P

OSIB

LES 

           

           

           

           

           

           

LESIO

NES 

GRAV

ES O

 MUE

RTE 

por e

lectr

ocuc

ión y

 PAR

A RE

DUC

IR EL

 RIES

GO D

E FU

EGO

   

— D

esco

necte

 toda

s las 

fuen

tes d

e ene

rgua

 eléct

rica y

 la 

       ba

tería

 ante

s de r

ealiz

ar ni

ngún

  serv

icio n

i man

tenim

iento

.

  

  

 

Insta

lar só

lo en

 luga

res se

cos —

 NO E

S PAR

A US

O EN

 EXTE

RIOR

ES.

Para 

su us

o sól

o con

 Gen

ie® m

odel

o de

 la se

rie 30

XX o

 

40XX

 abre

puer

tas re

siden

ciale

s par

a pue

rtas d

e gar

aje.

Utilic

e sólo

 Geni

e® P/N

 3734

3R co

mo b

atería

 de re

pues

to.

The

 Ge

nie 

Mo

del

 OB

B-B

X

PREC

AUC

IÓN

3831

0A

Insta

llez u

niqu

eme

nt da

ns de

s end

roits

 secs

 — P

AS D

ESTIN

E A E

TRE 

UTIL

ISE E

N PL

EIN A

IR.

A uti

lizer 

uniq

uem

ent a

vec G

enie

® mo

dèle

 de la

 série

 30X

ou 4

0XX 

pour

 port

es de

 gara

ge ré

siden

tielle

s.

Utilis

ez un

ique

men

t des

 Gen

ie® P

/N 37

343R

 com

me 

batte

rie d

e rep

lacem

ent.

         

         

         

         

         

   PO

UR É

VIER

 LES 

BLES

SURE

           

           

           

           

           

          G

RAVE

S OU

 LA M

ORT 

par  

élect

rocu

tion 

et PO

UR R

ÉDU

IRE E

S RIS

QUE

S DE

 FEU

  

— D

ébra

nche

s tou

tes le

s sou

rces d

’alim

enta

tion é

lectr

ique

s et 

       la

 bett

erie a

vant

 tout

e  rép

arati

on ou

 l’ent

retie

n.

  

  

 

ATTE

NTIO

N

®

US

The

 Ge

nie 

Mo

dèl

e O

BB-

BX

PowerMax®, SC, TriloG™, PowerLift™, SilentMax®, CB

and IntelliG® that are equipped with Series II electronics.  

 

  Choose mounting 

,   

Angle Iron Mount and Method 3 - Horizontal Mount 

 

and attach the mounting plate using screws provided.  

Method 1 - Ceiling Mount  Method 2 - 

Disconnect all electric power sources and battery power 

BEFORE performing ANY service or maintenance.

INSTALL ONLY IN DRY LOCATIONS. NOT FOR OUTDOOR USE.

 READ AND FOLLOW ALL SAFETY WARNINGS, CAUTIONS 

AND THESE ENTIRE INSTRUCTIONS PRIOR TO BEGINNING!

Mounting 

Plate

Connection

Cable

Battery 
Back-Up

TOOLS REQUIRED

Sockets and Ratchet

Flat Screwdriver

Lag Bolts (shown full size)

Installation 

Instructions

PARTS INCLUDED

7

/

16

1

/

4

 

Need help or have questions? 
DO NOT RETURN to the store. 
Call us: 800-354-3643 

Reviews: