30
EN
TroublEshooTiNg guidE
Power the installation off during cleaning operations or other maintenance
operations.
diagNosTics
rEPairs
The motor does not
respond to commands
from the remote
control
The remote control
range is reduced
- Check the remote control battery (see
"Changing the remote control battery",
next page).
- Check the aerial of the electronic unit
(wiring, position, see next page).
- Check that there are no outside
elements that are interfering with the
radio signal (electric pylon, metal
reinforced walls, etc.). If this is the
case, fit an external aerial.
Remote control not
memorised
Memorise the remote control (see page
19).
motor unlocked
Lock the motor.
The electronic unit's
sTaTus indicator
is off
Motor not powered - Check the power supply.
- Check the supply cable.
Outdoor lighting
very low = motor
on standby
Increase the light around the electronic
unit (using a torch, for example) if you
want to make adjustments.
The sTaTus
indicator of the
electronic unit is
flashing:
1 pulse
Operation using
the backup battery
Check the power supply.
2 pulses
Motor waiting for
gate travel to be
programmed
Begin the programming of the gate travel
(see page 14).
3 pulses
Cell fault:
- Cells blocked
Remove the obstacle blocking the cells.
- Cells misaligned
Correct their alignment (see page 23).
- Cells incorrectly
wired
Wire the cells following the instructions
on page 23.
- Cells missing/
disconnected
- Check that your cells are correctly
connected.
- If you have deliberately disconnected
the cells and your gate is operating in
auto close mode, you must deactivate
auto close mode (see page 20).
4 pulses
Short circuit on the
electronic unit BUS
output (terminals
3-4)
Check the accessories connected to the
electronic unit BUS output.